| Volume | 60 L |
| Sterilization Temperature | 105 to 135°C |
| Temperature Fluctuation | ±1°C |
| Temperature Uniformity | ±1°C |
| Heat Preservation Temperature | 40 to 60°C |
| Environment Temperature | 5 to 40°C |
| Environment Humidity | 20% to 80% RH |
| Melting Temperature | 50 to 100°C |
| Sterilization Timer Range | 0 to120 min |
| Melting Timer Range | 0 to 6000 min |
| Heat Preservation Timer Range | 0 to 6000 min |
| Reservation Range | 0 to 99hr60 min |
| Design Pressure | 0.38 MPa |
| Working Pressure | 0.22 MPa |
| Pressure gauge indicating Range | 0-0.4 MPa |
| Drum Diameter | 400 mm |
| Number of Baskets | 2 pc |
| Power Consumption | 3.2kW |
| Housing Dimensions [W×D×H] | 535 ×640 ×1075 mm |
| Basket Dimensions [W×D×H] | Ø360 ×230 mm |
| Package Dimensions [W×D×H] | 670 ×780 ×1240 mm |
| Net Weight | 100 kg |
| Gross Weight | 118 kg |
Our Vertical Autoclave ADVA-532 is widely used across industries such as healthcare for sterilizing surgical tools, pharmaceuticals for preparing sterile media.
1. How do you load materials in a Vertical Autoclave correctly?
When using a Vertical Autoclave, place items in a perforated basket or tray, ensuring there’s enough space for steam circulation. Do not overload the chamber and avoid stacking items too tightly to ensure effective sterilization.
2. Is it necessary to use distilled water in a Vertical Autoclave?
Yes, using distilled or demineralized water in a Vertical Autoclave helps prevent scale buildup on the heating element and chamber, which can reduce efficiency and cause damage over time.
3. What is a Vertical Autoclave and how does it work?
A Vertical Autoclave is a sterilization device that uses steam under pressure to sterilize equipment, media, and laboratory tools. It works by heating water to produce steam, which destroys bacteria, viruses, and other microorganisms.
4. What safety features are included in a Vertical Autoclave?
A Vertical Autoclave includes safety features like pressure release valves, temperature cut-offs, door interlocks, and alarms. These systems prevent accidental opening or overheating in the Vertical Autoclave. Built-in sensors ensure the unit shuts off in case of any malfunction.
5. Can a Vertical Autoclave be used for medical waste?
A Vertical Autoclave can be used to sterilize soft medical waste like gauze, gloves, and cloth items. However, a Vertical Autoclave may not be ideal for large volumes of waste or sharp objects. Special medical waste autoclaves are recommended for such loads.
| Volume | 50 L |
| Maximum Working Temperature | 135°C to 139°C |
| Maximum Working Pressure | 0.22 to 0.25 MPa |
| Chamber Volume | 100L φ (440×650) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Volume | 100 L |
| Maximum Working Temperature | 135°C to 139°C |
| Maximum Working Pressure | 0.22 to 0.25 MPa |
| Chamber Volume | 150L φ (510×740) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105°C to 135°C |
| Sterilizing chamber volume: | 150 L φ (440×1000mm) |
| working pressure: | 0.22Mpa |
| Working temperature: | 134ºC |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 280 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 280 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Sterilizing Chamber Volume: | 200 L φ (515×1000mm) |
| Working Pressure: | 0.22Mpa |
| Working Temperature: | 134ºC |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range : | 105 to 135°C |
| Chamber Volume: | 24L (280 × 390) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature : | 126℃ |
| Chamber Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 18 L (240×200) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Temperature Adjust Range: | 105℃ to 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L 80×260 mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 24L (280×390) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Chamber Volume: | 18L (280 × 260) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 24L φ (270×410) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 35L φ (300×500) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 20L φ (250×420) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 50L φ (340×550) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (250×520) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 16L φ (250×360) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |