Vertical Autoclave ADVA-520

Vertical Autoclave ADVA-520

Vertical Autoclave ADVA-520 works at a working pressure of 0.22MPa for effective sterilization. Its compact structure facilitates easy transportation without compromising performance. This unit is equipped with a pressure gauge and safety valve to maintain controlled internal pressure. The Autoclave is designed to operate with minimal water usage, making it ideal for resource-limited areas. Our Vertical Autoclave is used in research centers, food industries, and field hospitals to sterilize tools and equipment.

$ 2,600.00
Chamber Volume 100 L φ (318×450) mm
Working Pressure 0.22MPa
Working Temperature 134℃
Maximum Working Pressure 0.23Mpa
Heat Average ≤±1℃
Timer Scope 0 to 99min or 0 to 99hr 59min
Temperature Scope 105 to 134℃
Power Consumption 4.5 KW
Power Supply AC220V. 50Hz
Overall Dimension (L×B×H) 540×560×1250 mm
Transport Dimension (L×B×H) 680×630×1370 mm
Gross Weight 110 Kg
Net Weight 85 Kg
  • Water level indicator
  • Automatic air purging system
  • Safety locking mechanism
  • Heat-resistant handles
  • Double safety valve

Our Vertical Autoclave ADVA-520 is used in research laboratories, microbiology and educational institutions, for sterilizing tools and lab equipment ensuring contamination-free conditions.

Frequently Asked Questions of Vertical Autoclave ADVA-520

1. How often should a vertical autoclave be serviced?

Routine maintenance should be performed every 3 to 6 months depending on usage frequency. This includes checking the gasket, valves, sensors, and heating elements. Annual calibration and performance validation are recommended to ensure proper functioning. Regular maintenance prolongs the lifespan and maintains sterilization efficacy. Always follow the manufacturer’s service guidelines.

2. What is a vertical autoclave and how does it differ from a horizontal autoclave?

A vertical autoclave is a cylindrical sterilization unit that loads from the top and is commonly used in laboratories and smaller medical facilities. It uses steam under pressure to sterilize instruments, media, and glassware. Unlike horizontal autoclaves, which are typically larger and load from the front, vertical autoclaves are more compact and ideal for space-constrained environments. Horizontal models are better for higher throughput or bulkier loads. The main difference lies in size, loading orientation, and volume capacity.

3. What types of materials and instruments can be sterilized in a vertical autoclave?

Vertical Autoclave can sterilize a wide variety of items including surgical instruments, laboratory glassware, culture media, rubber materials, and some types of textiles. They are also suitable for sterilizing liquids like culture broth, provided proper containers and settings are used. However, items sensitive to heat or moisture, such as certain plastics or electronics, should not be autoclaved. It's essential to check material compatibility with high-pressure steam. Always follow the manufacturer's recommendations to avoid damaging the load.

4. What is the standard sterilization cycle time and temperature for a vertical autoclave?

The most commonly used cycle in a vertical autoclave is 121°C at 15 psi for about 15–30 minutes, depending on the load size and type. For more resistant materials or larger loads, 134°C may be used for shorter periods (around 4 minutes). Cycle time includes heating, holding (sterilization), and cooling phases. It’s important not to interrupt the cycle to ensure proper sterilization. Time and temperature must be verified using thermometers or biological indicators for critical applications.

5. How does a vertical autoclave work (basic working principle)?

A vertical autoclave works by generating high-pressure steam to destroy microorganisms on instruments and materials. The chamber is sealed, and water inside is heated to produce steam that fills the chamber. Pressure builds up, allowing the temperature to rise above 100°C, typically to 121–134°C. This high-pressure, high-temperature environment kills bacteria, viruses, fungi, and spores. Once the cycle completes, the pressure is released and items are cooled before removal.

Similar Products of Vertical Autoclave

Chamber Volume 35L φ (318×450) mm
Working Pressure 0.22MPa
Working Temperature 134℃

$1,680.00

Chamber Volume 75L φ (400×600) mm
Working Pressure 0.22MPa
Working Temperature 134℃

$4,070.00

Chamber Volume 100L φ (510×740) mm
Working Pressure 0.1 to 0.22MPa 0.1 to 0.22MPa
Working Temperature 120 to 134℃ 120 to 134℃

$1,560.00

Chamber Volume 50L φ (340×550) mm
Working Pressure 0.1 to 0.22MPa
Working Temperature 120 to 134℃

$1,260.00

Horizontal Autoclave

Horizontal Autoclave ADHA-505
Volume:360 L
Door Structure:spoke
Temperature Range:105 to 135°C

$16,220.00

Horizontal Autoclave ADHA-508
Sterilizing Chamber Volume:200 L φ (515×1000mm)
Working Pressure:0.22Mpa
Working Temperature:134ºC

$7,400.00

Horizontal Autoclave ADHA-507
Sterilizing chamber volume:150 L φ (440×1000mm)
working pressure:0.22Mpa
Working temperature:134ºC

$6,420.00

Horizontal Autoclave ADHA-506
Volume:500 L
Door Structure :spoke
Temperature Range :105°C to 135°C

$16,980.00

Horizontal Autoclave ADHA-502
Volume:360 L
Door Structure:spoke
Temperature Range :105 to 135°C

$17,890.00

Horizontal Autoclave ADHA-503
Volume:500 L
Door Structure :spoke
Temperature Range :105 to 135°C

$18,800.00

Horizontal Autoclave ADHA-501
Volume:280 L
Door Structure :spoke
Temperature Range :105 to 135°C

$15,460.00

Horizontal Autoclave ADHA-504
Volume:280 L
Door Structure:spoke
Temperature Range:105 to 135°C

$13,640.00

Portable Autoclave

Portable Autoclave ADPA-506
Sterilizing Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16MPa
Working Temperature:126 ºC
Portable Autoclave ADPA-507
Chamber Volume:12L (240×200) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-508
Chamber Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-502
Sterilizing Volume:18L 80×260 mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-509
Chamber Volume:24L (280×390) mm
Working Pressure:0.14 to 0.16Mpa
Working Temperature:126℃
Portable Autoclave ADPA-505
Working Pressure:0.14 to 0.16MPa
Working Temperature:126 ºC
Temperature Adjust Range:105℃ to 126℃
Portable Autoclave ADPA-501
Sterilizing Volume:18L (280×260) mm
Working Pressure:0.14 to 0.16MPa
Working Temperature:126℃
Portable Autoclave ADPA-503
Chamber Volume:18L (280 × 260) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature:126℃
Portable Autoclave ADPA-504
Chamber Volume:24L (280 × 390) mm
Working Pressure:0.14 to 0.16 MPa
Working Temperature :126℃

Benchtop Autoclave

Benchtop Autoclave ADBA-506
Chamber Volume:50L φ (340×550) mm
Working Pressure:0.22MPa
Working Temperature:134℃

$4,090.00

Benchtop Autoclave ADBA-504
Chamber Volume:24L φ (250×520) mm
Working Pressure:0.22MPa
Working Temperature:134℃

$1,610.00

Benchtop Autoclave ADBA-501
Chamber Volume:16L φ (250×360) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-502
Chamber Volume:24L φ (270×410) mm
Working Pressure:0.22MPa
Working Temperature:134℃
Benchtop Autoclave ADBA-505
Chamber Volume:35L φ (300×500) mm
Working Pressure:0.22MPa
Working Temperature:134℃

$3,340.00

Benchtop Autoclave ADBA-503
Chamber Volume:20L φ (250×420) mm
Working Pressure:0.22MPa
Working Temperature:134℃

$1,400.00