| Chamber Volume | 75L φ (400×600) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Maximum Working Pressure | 0.23Mpa |
| Heat Average | ≤±1℃ |
| Timer Scope | 0 to 60 min |
| Temperature Scope | 105 to 134℃ |
| Power Consumption | 4.5 KW |
| Power Supply | AC220V. 50Hz |
| Overall Dimension (L×B×H) | 560×560×1120 mm |
| Transport Dimension (L×B×H) | 650×630×1280 mm |
| Gross Weight | 100 Kg |
| Net Weight | 80 Kg |
Our Vertical Autoclave ADVA-515 is widely used across industries such as healthcare for sterilizing surgical tools, pharmaceuticals for preparing sterile media, and research laboratories for ensuring aseptic experimental conditions.
1. Do vertical autoclaves require distilled water?
Yes, using distilled or deionized water is recommended to prevent scaling and mineral buildup. Tap water can damage internal components and reduce heating efficiency. Distilled water extends the life of the autoclave and maintains sterilization performance. Regular water tank cleaning is also important. Always follow manufacturer specifications for water quality.
2. What power supply is required for a vertical autoclave?
Vertical autoclave operate on standard voltages such as 220V or 110V depending on the region. Some larger models may require a three-phase power connection. Always check the power rating and ensure proper grounding. Using a voltage stabilizer may be advised in areas with fluctuating power. Incorrect voltage can damage the unit or affect performance.
3. Can liquids be sterilized in a vertical autoclave?
Yes, liquids like culture media and reagents can be sterilized using special liquid cycles. These cycles control depressurization to prevent boiling over and ensure safety. Liquids should be in heat-resistant, loosely capped containers. The process takes longer due to slow pressure release. Proper load arrangement is essential to ensure even steam penetration.
4. ow often should vertical autoclaves be calibrated?
Calibration should be done at least annually or according to your facility’s quality management system. Calibration ensures accurate temperature and pressure readings. Some institutions may require more frequent calibration for regulatory compliance. Always use certified calibration equipment and trained technicians. Accurate calibration is critical for validated sterilization cycles.
5. What is a vertical autoclave?
A vertical autoclave is a cylindrical sterilization device used to decontaminate laboratory and medical instruments using high-pressure steam. It is designed with a top-loading configuration, making it compact and efficient for smaller spaces. These units are widely used in laboratories, hospitals, and research facilities. The sterilization process typically involves temperatures between 121°C to 134°C. Vertical autoclaves are ideal for sterilizing liquids, glassware, and instruments.
6. What is a Vertical Autoclave and how does it work?
A Vertical Autoclave is a sterilization device that uses steam under pressure to sterilize equipment, media, and laboratory tools. It works by heating water to produce steam, which destroys bacteria, viruses, and other microorganisms.
7. What safety features are included in a Vertical Autoclave?
A Vertical Autoclave includes safety features like pressure release valves, temperature cut-offs, door interlocks, and alarms. These systems prevent accidental opening or overheating in the Vertical Autoclave. Built-in sensors ensure the unit shuts off in case of any malfunction.
8. Can a Vertical Autoclave be used for medical waste?
A Vertical Autoclave can be used to sterilize soft medical waste like gauze, gloves, and cloth items. However, a Vertical Autoclave may not be ideal for large volumes of waste or sharp objects. Special medical waste autoclaves are recommended for such loads.
| Chamber Volume | 50L(φ340×550) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Chamber Volume | 35L φ (318×450) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Volume | 100 L |
| Maximum Working Temperature | 135°C to 139°C |
| Maximum Working Pressure | 0.22 to 0.25 MPa |
| Chamber Volume | 100L φ (440×650) mm |
| Working Pressure | 0.22MPa |
| Working Temperature | 134℃ |
| Volume: | 280 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 280 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range : | 105 to 135°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105 to 135°C |
| Sterilizing chamber volume: | 150 L φ (440×1000mm) |
| working pressure: | 0.22Mpa |
| Working temperature: | 134ºC |
| Sterilizing Chamber Volume: | 200 L φ (515×1000mm) |
| Working Pressure: | 0.22Mpa |
| Working Temperature: | 134ºC |
| Volume: | 360 L |
| Door Structure: | spoke |
| Temperature Range: | 105 to 135°C |
| Volume: | 500 L |
| Door Structure : | spoke |
| Temperature Range : | 105°C to 135°C |
| Chamber Volume: | 12L (240×200) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Chamber Volume: | 24L (280 × 390) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature : | 126℃ |
| Chamber Volume: | 18L (280 × 260) mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126 ºC |
| Temperature Adjust Range: | 105℃ to 126℃ |
| Chamber Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L 80×260 mm |
| Working Pressure: | 0.14 to 0.16 MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 24L (280×390) mm |
| Working Pressure: | 0.14 to 0.16Mpa |
| Working Temperature: | 126℃ |
| Sterilizing Volume: | 18L (280×260) mm |
| Working Pressure: | 0.14 to 0.16MPa |
| Working Temperature: | 126℃ |
| Chamber Volume: | 16L φ (250×360) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 50L φ (340×550) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (270×410) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 20L φ (250×420) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 24L φ (250×520) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |
| Chamber Volume: | 35L φ (300×500) mm |
| Working Pressure: | 0.22MPa |
| Working Temperature: | 134℃ |