Automated Cell Counter ADACC-503

Automated Cell Counter ADACC-503

Automated Cell Counter ADACC-503 with fast detection time of 20 to 30 seconds for assessing cell concentration. The user-friendly touchscreen interface simplifies operation and enhances overall usability. This unit often includes automatic dilution for consistent sample preparation. It utilizes high-resolution imaging to distinguish between live and dead cells with precision. Our Automated Cell Counter is used in diagnostics, stem cell therapy, and biotechnology for accurately measuring cell viability.


Sample Volume 10 µl
Sample Concentration 1×10⁴ to 2×10⁷cells/mL, maximum at 4 ×10⁷ cells/mL
Detection of Particle Size 3 to 30 µm
Detection Time 20 to 30 sec, depends on the cell concentration
Image Module Yes
Image Magnification 5X
Dye Used Trypan-blue
Automatic Dyeing Module Yes
Automatic Cleaning Yes
Diameter of the District Yes
Dilution Calculator Yes
Data Input and Output USB 2.0; all in one
Coefficient of Variation ≤5%
Net Weight 11.5 Kg
Gross Weight 13 Kg
  • Fluorescence capabilities
  • Accurate cell quantification
  • Compact and portable designs
  • Integrated imaging
  • User-friendly interface

Our Automated Cell Counter ADACC-503 is used in cancer research, vaccine production and microbiology for rapid cell counting.

Frequently Asked Questions of Automated Cell Counter ADACC-503

1. How do I prepare a sample for Automated Cell Counter ADACC-503?

Sample preparation typically involves creating a uniform cell suspension with the appropriate concentration. Clumping should be avoided, often by gently pipetting or using enzymatic treatment like trypsinization. Debris should be minimized as it can interfere with accurate counts. it requires dilution or the addition of specific reagents or dyes. Proper mixing and loading technique is essential to ensure accurate and reliable results.

2. Do I need to use stains or dyes with an Automated Cell Counter ADACC-503?

Stains or dyes are often used to differentiate between live and dead cells in Automated Cell Counter ADACC-503. Trypan Blue is one of the most commonly used dyes for viability assessment. It uses fluorescence-based stains for more advanced analysis. However, basic total cell counts can sometimes be done without any staining, depending on the device.

3. How accurate is an Automated Cell Counter ADACC-503 compared to manual counting?

Automated Cell Counter ADACC-503 is generally more accurate and consistent than manual methods, especially when counting large numbers of samples. It reduces human error, fatigue, and variability between users. Accuracy can still be influenced by factors such as sample preparation and debris in the sample. It offers high reproducibility and are validated against manual hemocytometer counts.

4. What types of cells can be counted with an Automated Cell Counter ADACC-503?

Automated Cell Counter ADACC-503 is versatile and can handle a wide range of cell types including mammalian cells, yeast, algae, and some types of bacteria. It is particularly useful in tissue culture labs, bioprocessing, and clinical research. It comes with specialized settings or reagents for specific cell lines or applications. Viable and non-viable cells can also be distinguished using dye-based methods.

5. What is an Automated Cell Counter ADACC-503 and how does it work?

An Automated Cell Counter ADACC-503 is a laboratory instrument used to quickly and accurately count cells in a liquid sample. It uses imaging technology, electrical impedance, or flow cytometry to detect and analyze individual cells. It can also provide data on cell viability, size, and concentration. By automating the process, it eliminates the subjectivity and time required in manual counting using a hemocytometer.

Similar Products of Automated Cell Counter

Sample Volume 10µl
Sample Concentration 1×10⁴ to 1×10⁷ cells/mL
Detection of Particle Size 3 to 30 µm
Sample Volume 10 µl
Sample Concentration 1×10⁴ to 2×10⁷cells/mL, maximum at 4 ×10⁷ cells/mL
Detection of Particle Size 3 to 30 µm

Microbial Cell Counter

Microbial Cell Counter ADCMC-501
Sample Volume:10 µl
Sample Concentration:5×10⁴ to 2×10⁷cells/mL
Coefficient of Variation:≤10%