| Temperature Control Range | RT +5℃ to 60℃ |
| Temperature Set Range | 0℃ to 60℃ |
| Temperature Precision | ≤ ±0.3℃ at 37℃ |
| Temperature Display | 0.1℃ |
| Temperature Uniformity | ≤ ±0.5℃ at 37℃ |
| Amplitude | 20 mm |
| Speed Range | 50 to 300 rpm |
| Platform Dimension | 310×310 mm |
| Maximum Height of Vessel | 305 mm |
| Maximum Load | 5 kg |
| Timer | 1 min to 99 h / infinite |
| Power Consumption | 650 W |
| Power Supply | AC100 to 120V / AC210 to 240V |
| Dimension (W×D×H) | 400×630×490 mm |
| Net Weight | 37 kg |
Our Shaking Incubator ADSI-504 is ideal for cell and tissue culture, fermentation, hybridization, and biochemical reactions in medical, biological, pharmaceutical, food safety, and environmental research.
Accessory | Dimension | Flask type and Capacity | Quantity |
Flat platform with non-slip mat | 315×315 mm | - | 1 Pc |
Universal platform with springs | 310×310×45 mm | - | 1 Pc |
Platform with clamps 01 | 315×315 mm | 50 ml×25 or 100 ml×16 or 250 ml×9 | 1 Pc |
Platform with clamps 02 | 315×315 mm | 500 ml×5 or 1000 ml×4 or 2000 ml×2 | 1 Pc |
Platform with adhesive mats | 315×315 mm | 50 ml×25 or 50 ml×16 or 250 ml×9 or 500 ml×5 or 1L×4 or 2 L×2 | 4 Pcs |
Adhesive mat | 315×315 mm | - | 1 Pc |
1. What is the size of the touchscreen on the Shaking Incubator?
This Shaking Incubator features a 4.3-inch colorful TFT touchscreen. This screen provides a clear and intuitive interface for easy control and monitoring. The vibrant display enhances visibility even in low-light laboratory environments. It supports precise adjustments of temperature, shaking speed, and time settings, improving overall user experience.
2. What is the maximum load capacity of the Shaking Incubator?
Our Shaking Incubator is designed to support a maximum load of 5 kg. This capacity ensures optimal performance and safety during operation. It's important to adhere to this weight limit to maintain the integrity of the equipment and prevent potential damage. Always distribute the load evenly across the platform to ensure balanced shaking and accurate results.
3. Does the Shaking Incubator come with optional platforms?
Yes, this Shaking Incubator offers optional platforms to accommodate different types of containers and experiment needs. These platforms enhance versatility by allowing users to customize the setup for various flask sizes, tubes, or plates. Optional platforms make the incubator adaptable for a wide range of laboratory applications.
4. What ensures stable high-speed operation in the Shaking Incubator?
Our Shaking Incubator is equipped with a unique balance system that guarantees stable and smooth high-speed running. This system minimizes vibrations and noise, ensuring reliable performance even at maximum shaking speeds. It enhances the durability of the equipment and improves experiment accuracy by maintaining consistent motion.
5. What safety features does the Shaking Incubator have regarding temperature and lid operation?
This Shaking Incubator includes over-temperature protection to prevent overheating and ensure safe operation. It has a safeguard that automatically stops the shaking when the lid is opened, protecting both the user and the samples. These features help maintain a safe working environment and prevent damage to the equipment.
6. What is a Shaking Incubator?
A Shaking Incubator is a laboratory device that combines temperature-controlled incubation with orbital shaking. It's commonly used for growing cultures of bacteria, yeast, and other microorganisms that require aeration. It ensures uniform mixing and optimal oxygen transfer, which are critical for efficient microbial growth.
7. How does a Shaking Incubator differ from a regular incubator?
A regular incubator maintains a stable temperature, while a Shaking Incubator also provides continuous shaking to ensure proper mixing and aeration, which is essential for growing aerobic organisms. The shaking action helps prevent sedimentation of cells and promotes even nutrient distribution. This makes shaking incubators ideal for applications like cell culture, fermentation, and protein expression studies.
8. What are the maintenance requirements in Shaking Incubator?
Regular maintenance of a Shaking Incubator includes cleaning the chamber to prevent contamination and ensure optimal hygiene. It's important to lubricate moving parts as recommended by the manufacturer to maintain smooth operation. Periodic calibration of temperature and shaking speed controls ensures accuracy and reliability. Users should routinely check for unusual vibrations, noises, or signs of wear to prevent potential malfunctions.
| Capacity | 170 L |
| Speed | 40 to 300 rpm |
| Maximum Volume | 100 mL × 48 / 250 mL × 25 |
| Shaking Speed | 50 to 300 rpm |
| Orbit | 20 mm |
| Load Capacity | 4.0 kg |
| Temperature Range |
Incubation: 5℃ to 60℃ Refrigeration: 4℃ to 60℃ |
| Temperature Accuracy | 0.1℃ |
| Temperature Uniformity | ≤±1℃ [37℃] |
| Capacity | 285 L |
| Speed | 40 to 300 rpm |
| Maximum Volume | 250 mL × 35 / 500 mL × 25 |