| Capacity | 128 L |
| Temperature Range | -40 to -86°C |
| Cooling Performance | -80 °C |
| Cabinet Type | Chest |
| Cooling Type | Direct cooling |
| Defrost Mode | Manual |
| Refrigerant | HC mixed |
| Display | 7" Touch screen with USB port |
| Interior Material | Stainess steel |
| Exterior Material | Galvanized steel powder coating |
| Insulation Material | PUF+VIP |
| High and Low Temperature Alarm | Yes |
| Hot Condenser | Yes |
| High Ambient Temp | Yes |
| Sensor Failure Alarm | Yes |
| Alarm Mode | Sound and light alarm, remote alarm terminal |
| Thickness of Cabinet Foamed Layer | 90 mm |
| Inner Door Number | 2 |
| Capacity for 2-inch boxes | 96 |
| Container Loading | 36/72 (20'/40') |
| Thickness of Door | 90 mm |
| Door Locking Device | Yes |
| Handle | Yes |
| Pressure Balance Hole | Yes |
| Caster | Yes |
| Test Hole | Yes |
| Climate Class | No |
| Temperature Recorder | Optional |
| Racks & Boxes | Optional |
| Energy consumption | 6.8 KW.H/24H |
| Power Supply | 220/50 V/Hz |
| Power Consumption | 480 W |
| Interior Dimensions (W×D×H) | 630 x 440 x 470 mm |
| Exterior Dimensions (W×D×H) | 850 x 740 x 1025 mm |
| Packing Dimensions (W×D×H) | 930 x 780 x 1160 mm |
| Net Weight | 98 kg |
| Gross Weight | 116 kg |
Our -80°C Ultra Low Vertical Freezer ADFU-501 is utilized in medical centers, biobanks, laboratories, and industrial settings for extended storage of fragile biological substances such as tissues, cells, and viruses.
1. What is the capacity of the -86°C Ultra Low Vertical Freezer ADFU-501?
-86°C Ultra Low Vertical Freezer ADFU-501 features a 128-liter internal volume, making it suitable for compact spaces while accommodating a wide variety of critical specimens. Despite its size, the chamber allows efficient arrangement of cryo boxes. It is ideal for laboratories that require moderate sample storage with limited footprint.
2. What temperature range does the -86°C Ultra Low Vertical Freezer ADFU-501 support?
The -86°C Ultra Low Vertical Freezer ADFU-501 maintains ultra-low cooling between -40°C and -86°C, ensuring safe preservation of fragile samples. This range is ideal for preserving RNA, cell lines, plasma, and viral cultures. Uniform cooling performance across the unit reduces the risk of temperature variations.
3. How does the defrost mechanism work in -86°C Ultra Low Vertical Freezer ADFU-501?
-86°C Ultra Low Vertical Freezer ADFU-501 uses a manual defrost system, allowing users to efficiently manage ice buildup and maintain consistent thermal performance. This method helps reduce mechanical failures and prolongs equipment lifespan. Routine defrosting also ensures energy efficiency and cleaner sample environments.
4. What insulation and safety mechanisms are built into the -86°C Ultra Low Vertical Freezer ADFU-501?
-86°C Ultra Low Vertical Freezer ADFU-501 incorporates high-efficiency polyurethane foam insulation, ensuring minimal temperature fluctuations and energy loss. It includes a safety door lock to restrict unauthorized access, buzzer alarms for operational anomalies, and visual indicators for fault detection. These features collectively help protect stored specimens while maintaining a secure, ultra-low environment.
5. How does the -86°C Ultra Low Vertical Freezer ADFU-501 ensure temperature stability?
A microprocessor-based control panel, combined with reliable compressor technology, maintains uniform internal conditions even during power fluctuations. Alarms and LED indicators provide real-time alerts in case of abnormal operations. The unit is equipped with internal memory to log and monitor temperature data.
6. What are -86°C Ultra Low Vertical Freezers used for?
They are designed for preserving sensitive biological samples, pharmaceuticals, and research specimens under extreme cold environments in labs and clinics. These units are essential for storing biological samples that require consistent ultra-low temperatures. Their vertical design maximizes floor space while allowing organized compartmentalized storage. With stable temperature performance, they ensure sample integrity over extended durations.
7. How do -86°C Ultra Low Vertical Freezers differ from -86°C Ultra Low Temperature Freezers? -
-86°C Ultra Low Vertical Freezers are distinguished by their upright, space-saving design, allowing easier access and organized shelving for high-volume storage. While both types maintain the same temperature range, vertical units offer ergonomic advantages of stored samples compared to horizontal. Ultra Low Temperature Freezers, which are often preferred for higher thermal stability.
| Capacity | 480 L |
| Temperature Range | -40 to -86°C |
| Cooling Performance | -80 °C |
| Capacity | 588 L |
| Temperature | 40 °C to 86 °C |
| Compressor | 2 |
| Capacity | 728 L |
| Temperature | 40 °C to 86 °C |
| Compressor | 2 |
| Capacity | 408 L |
| Temperature | 40 °C to 86 °C |
| Compressor | 1 |
| Capacity: | 96 L |
| Temperature Range: | -40°C to -86°C |
| Cooling Performance : | -80 °C |
| Capacity: | 480 L |
| Temperature Range : | -40 to -86°C |
| Cooling Performance : | -80 °C |
| Capacity: | 590 L |
| Temperature Range: | -40 to -86°C |
| Cooling Performance : | -80 °C |
| Capacity: | 730 L |
| Temperature Range: | -40 to -86°C |
| Cooling Performance : | -80 °C |
| Capacity: | 360 L |
| Temperature Range : | -40 to -86°C |
| Cooling Performance : | -80 °C |
| Capacity: | 280 L |
| Temperature Range: | -40°C to -86°C |
| Cooling Performance : | -80 °C |
| Capacity: | 1018 L |
| Temperature Range: | -40 to -86°C |
| Cooling Performance : | -80 °C |
| Capacity: | 380 L |
| Temperature Range: | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 580 L |
| Temperature Range: | -15°C to -25°C |
| Cooling Method: | Direct Cooling |
| Capacity: | 470 L |
| Temperature Range : | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 100 L |
| Temperature Range : | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 190 L |
| Temperature Range : | -10 to -25°C |
| Cooling Performance: | -25°C |
| Capacity: | 285 L |
| Temperature Range : | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 110 L |
| Temperature Range : | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 520 L |
| Temperature Range : | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 260 L |
| Temperature Range: | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 390 L |
| Temperature Range: | -10 to -25°C |
| Cooling Performance : | -25°C |
| Capacity: | 60 L |
| Temperature Range: | -10 to -25°C |
| Cooling Performance: | -25°C |
| Capacity: | 500 L |
| Temperature Range: | -30 to -60°C |
| Cooling Performance: | -60 °C |
| Capacity: | 270 L |
| Temperature Range : | -30 to -60°C |
| Cooling: | -60°C |
| Capacity: | 100 L |
| Temperature Range : | -30 to -60°C |
| Cooling: | -60°C |
| Capacity: | 170 L |
| Temperature Range : | -30 to -60°C |
| Cooling: | -60°C |
| Capacity: | 370 L |
| Temperature Range: | -30 to -60°C |
| Cooling Performance : | -60 °C |
| Capacity: | 100 L |
| Temperature Range : | -10 to -40°C |
| Cooling Performance : | -40°C |
| Capacity: | 190 L |
| Temperature Range : | -10 to -40°C |
| Cooling Performance : | -40°C |
| Capacity: | 285 L |
| Temperature Range: | -10 to -40°C |
| Cooling Performance : | -40°C |
| Capacity: | 470 L |
| Temperature Range: | -10 to -40°C |
| Cooling Performance : | -40°C |
| Capacity: | 380 L |
| Temperature Range : | -10 to -40°C |
| Cooling Performance : | -40°C |
| Capacity: | 226 L |
| Temperature Range : | -125 to -150°C |
| Cooling Performance : | -150 °C |
| Capacity: | 138 L |
| Temperature Range: | -125 to -150°C |
| Cooling Performance : | -150 °C |
| Capacity: | 290 L |
| Temperature Range : | -10 to -40°C |
| Cooling Performance -: | -40°C |
| Capacity: | 370 L |
| Temperature Range : | -10 to -40°C |
| Cooling Performance : | -40°C |
| Capacity: | 599 L |
| Temperature Range : | -10 to -40°C |
| Cooling Performance : | -40°C |
| Capacity: | 608 L |
| Temperature Range: | 0 to -40°C |
| Cooling Performance: | -40°C |
| Capacity: | 580 L |
| Temperature Range: | -10 to -30°C |
| Cooling Performance : | -25°C |
| Capacity: | 1050 L |
| Temperature Range : | -10 to -30°C |
| Cooling Performance : | -25°C |
| Capacity: | 300 L |
| Temperature Range: | −10°C to −20°C (Adjustable) |
| Temperature Control: | Microprocessor-Based Digital Control |