Digital Electronic Balance ADDL-514

Digital Electronic Balance ADDL-514

Digital Electronic Balance ADDL-514 handles up to 600 g, ideal for precise and accurate weighing tasks. It offers reliable precision and maintains consistent results, even with regular usage. The unit ensures stable accuracy throughout the full weighing capacity. Its integrated tare function allows effortless deduction of container weight for true sample measurement. This Digital Electronic Balance is used in laboratories, educational environments, and industrial applications requiring exact material assessment.


Capacity 600 g
Readability 0.01 g
Repeatability ±0.01 g
Linearity ±0.02 g
Calibration External
Pan Dimensions 130 mm
Housing Dimensions (L × W × H) 300 × 190 × 100 mm
Packaging Dimensions (L × W × H) 320 × 280 × 150 mm
Net Weight 1.2 kg
  • LCD display
  • AC/DC operation
  • Loadcell protection
  • External calibration
  • Adjustable feet

The Digital Electronic Balance ADDL-514 is used in laboratories to accurately measure small sample quantities, supporting analytical precision and improving reliability in quality control procedures.

Digital Electronic Balance ADDL-514 | Capacity	600 g | Readability	0.01 g
Digital Electronic Balance ADDL-514 | LCD display | AC/DC operation

Frequently Asked Questions of Digital Electronic Balance ADDL-514

1. What is the maximum weighing capacity of the Digital Electronic Balance ADDL-514?

This Digital Electronic Balance ADDL-514 can accurately weigh up to 600 grams, making it suitable for a variety of precision tasks in environments requiring exact low-range measurements. Its compact design supports delicate applications such as chemical dosing, micro-sample preparation, and lab-based material evaluation.

2. Does the Digital Electronic Balance ADDL-514 come with a tare function, and how does it assist users?

Yes, the Digital Electronic Balance ADDL-514 includes a built-in tare feature, allowing users to reset the display to zero after placing a container. This function ensures that only the net weight of the contents is measured, eliminating the influence of the vessel. It enhances precision in sample weighing and streamlines procedures that involve frequent use of containers.

3. How does the Digital Electronic Balance ADDL-514 maintain high accuracy with frequent use?

The Digital Electronic Balance ADDL-514 is designed with precision load sensors and a stable internal architecture that safeguard measurement integrity over time. Even during continuous operation, it preserves calibration consistency and minimizes drift. This ensures reliable data for repetitive weighing routines, supporting quality control and analytical precision.

4. How does the Digital Electronic Balance ADDL-514 improve laboratory workflow and efficiency?

With its quick response time and user-friendly operation panel, the Digital Electronic Balance ADDL-514 minimizes delays and supports faster throughput. The interface is intuitive, reducing training time and helping user's complete tasks efficiently. Its design makes it ideal for time-sensitive procedures and multi-step workflows.

5. What kind of screen does the Digital Electronic Balance ADDL-514 offer for reading values?

Equipped with a high-visibility LCD panel, the Digital Electronic Balance ADDL-514 delivers clear, legible readings in a wide range of lighting conditions. The backlit display ensures user comfort during extended use and helps reduce errors by enhancing digit clarity. This makes it dependable for fast-paced environments and detailed analysis.

6. What are Digital Electronic Balances?

Digital Electronic Balances are highly precise weighing instruments that use electronic sensors to determine the mass of various substances. They display measurements digitally, significantly reducing human error associated with analog scales. These instruments are engineered to deliver accurate, quick, and consistent results. Equipped with advanced features like automatic calibration, tare functionality, and multi-unit conversion.

7. In what way do temperature fluctuations impact the performance of Digital Electronic Balances?

Temperature variations can affect the accuracy and stability of Digital Electronic Balances. Sudden changes may cause thermal drift, leading to inconsistent or inaccurate readings. To ensure reliable performance, balances should be used in temperature-controlled environments and allowed to acclimate before weighing.

Similar Products of Digital Electronic Balance

Capacity 600 g
Readability 0.1 g
Repeatability ±0.1 g
Capacity 200 g
Readability 0.001 g
Repeatability ±0.002 g
Capacity 6000 g
Readability 1 g
Repeatability ±1 g
Capacity 10000 g
Readability 0.1 g
Repeatability ±0.1 g

Analytical Balance

Analytical Balance ADAB-503
Capacity:200g
Repeatability:±0.0002 g
Linearity:±0.0003g
Analytical Balance ADAB-505
Capacity:220 g
Readability:0.0001 g
Minimum Weighing:0.0004 g
Analytical Balance ADAB-501
Capacity:100g
Repeatability:±0.0002 g
Linearity:±0.0003g
Analytical Balance ADAB-506
Capacity:0 to 50 g
Readability:0.01 mg
Stabilization Time:≤13 s
Analytical Balance ADAB-504
Capacity:210g
Repeatability:±0.0002 g
Linearity:±0.0003g
Analytical Balance ADAB-502
Capacity:110g
Repeatability:±0.0002 g
Linearity:±0.0003g

Precision Balance

Precision Balance ADPB-504
Capacity:2100 g
Readability:0.1 g
Linearity:±0.3 g
Precision Balance ADPB-508
Capacity:10000 g
Readability:0.1 g
Linearity:±0.3 g
Precision Balance ADPB-502
Capacity:610 g
Readability:0.1 g
Linearity:±0.3 g
Precision Balance ADPB-507
Capacity:6100 g
Readability:0.1 g
Linearity:±0.3 g
Precision Balance ADPB-505
Capacity:3100 g
Readability:0.1 g
Linearity:±0.3 g
Precision Balance ADPB-501
Capacity:310 g
Readability:0.1 g
Linearity:±0.3 g
Precision Balance ADPB-506
Capacity:5100 g
Readability:0.1 g
Linearity:±0.3 g
Precision Balance ADPB-503
Capacity:1100 g
Readability:0.1 g
Linearity:±0.3 g

Desktop Balance

Desktop Balance ADDK-503
Capacity:150 kg
Readability:1 g
Repeatability:±2 g
Desktop Balance ADDK-504
Capacity:60 kg
Readability:10 g
Repeatability:±20 g
Desktop Balance ADDK-505
Capacity:100 kg
Readability:10 g
Repeatability:±20 g
Desktop Balance ADDK-501
Capacity:60 kg
Readability:1 g
Repeatability:±2 g
Desktop Balance ADDK-502
Capacity:100 kg
Readability:1 g
Repeatability:±2 g
Desktop Balance ADDK-507
Capacity:200 kg
Readability:10 g
Repeatability:±20 g
Desktop Balance ADDK-508
Capacity:300 Kg
Readability:10 g
Repeatability:±20 g
Desktop Balance ADDK-506
Capacity:150 kg
Readability:10 g
Repeatability:±20 g

Digital Precision Balance

Digital Precision Balance ADPD-502
Capacity:310 g
Resolution :0.01 g
Minimum Weighing :0.04 g
Digital Precision Balance ADPD-511
Capacity:200 g
Readability :1 mg
Repeatability:1 mg
Digital Precision Balance ADPD-501
Capacity:210 g
Resolution :0.01 g
Minimum Weighing :0.04 g
Digital Precision Balance ADPD-503
Capacity:510 g
Resolution :0.01 g
Minimum Weighing :0.04 g
Digital Precision Balance ADPE-501
Capacity:100 g
Readability:1 g
Repeatability:2 g
Digital Precision Balance ADPD-510
Capacity:100 g
Readability :1 mg
Repeatability:1 mg
Digital Precision Balance ADPD-504
Capacity:610 g
Resolution :0.01 g
Minimum Weighing :0.04 g
Digital Precision Balance ADPD-505
Capacity:1100 g
Resolution :0.01 g
Minimum Weighing :0.04 g
Digital Precision Balance ADPE-502
Capacity:200 g
Readability:1 g
Repeatability:2 g
Digital Precision Balance ADPD-513
Capacity:500 g
Readability :1 mg
Repeatability :1 mg
Digital Precision Balance ADPD-512
Capacity:300 g
Readability :1 mg
Repeatability:1 mg
Digital Precision Balance ADPE-504
Capacity:500 g
Readability:1 g
Repeatability:2 g
Digital Precision Balance ADPD-506
Capacity:2100 g
Resolution :0.01 g
Minimum Weighing :0.04 g
Digital Precision Balance ADPD-509
Capacity: 60 g
Readability :1 mg
Repeatability :1 mg
Digital Precision Balance ADPD-508
Capacity:3100 g
Readability:0.01 g
Pan Size:Ø 130 mm
Digital Precision Balance ADPD-507
Capacity:3100 g
Resolution :0.01 g
Minimum Weighing :0.04 g
Digital Precision Balance ADPE-503
Capacity:300 g
Readability:1 g
Repeatability:2 g

Electronic Analytical Balance

Electronic Analytical Balance ADEA-503
Capacity:120 g
Readability:0.1 g
Repeatability:± 0.2 g
Electronic Analytical Balance ADEA-505
Capacity:220 g
Readability:0.1 g
Repeatability:± 0.2 g
Electronic Analytical Balance ADEA-504
Capacity:200 g
Readability:0.1 g
Repeatability:± 0.2 g
Electronic Analytical Balance ADEA-501
Capacity:60 g
Readability:0.1 g
Repeatability:± 0.2 g
Electronic Analytical Balance ADEA-502
Capacity:100 g
Readability:0.1 g
Repeatability:± 0.2 g
Electronic Analytical Balance ADEA-506
Capacity:300 g
Readability:0.1 g
Repeatability:± 0.2 g

Hydrostatic Balance

Hydrostatic Balance ADHHB-501
Capacity:2000g
Accuracy:0.01g
Linearity Error:±0.03g
Hydrostatic Balance ADHHB-503
Capacity:2000g
Accuracy:0.1g
Linearity error:±0.3g
Hydrostatic Balance ADHHB-504
Capacity:5000g
Accuracy:0.1g
Linearity error:±0.3g
Hydrostatic Balance ADHHB-502
Capacity:5000g
Accuracy:0.01 g
Linearity error:±0.03g