Drug Stability Test Chamber ADDST-503
Drug Test Chamber ADTC-502
Drug Stability Test Chamber ADDST-503 (front view)
Drug Stability Test Chamber ADDST-503 (side view)

Drug Stability Test Chamber ADDST-503

Our Drug Stability Test Chamber ADDST-503 provides a controlled humidity range of 40 to 95% RH, for pharmaceutical stability testing. It features a thirty-stage microprocessor PID controller for reliable environmental regulation. Uniform airflow is maintained throughout the system using a forced convection unit. Double-layer insulation design improves energy efficiency by minimizing heat loss. This Drug Stability Test Chamber is well-suited for GMP-compliant studies, long-term drug trials, and shelf-life testing.

USD 9,060.00
Temperature Range 0 to 65℃
Humidity Range 40 to 95% RH
Temperature Accuracy ±0.1℃
Temperature Fluctuation ±0.5℃ (within 10 to 40℃)
Temperature Uniformity ±1℃ (within 10 to 40℃)
Humidity Fluctuation ±3% RH
Internal Volume 250 Liters
Working Environment 10 to 30℃
Working Environment (Humidity) below 70%
Power Consumption 1100 W
Power Supply AC 220V to 50Hz
Internal Dimensions (H×W×D) 1100 × 510 × 450 mm
External Dimensions (H×W×D) 1730 × 650 × 740 mm
Shipping Dimensions (H×W×D) 1930 × 750 × 890 mm
Net Weight 135 kg
Gross Weight 162 kg
  • Quick defrost cycle
  • Advanced Cooling System
  • Clear system display
  • User-friendly interface
  • Seamless operation

Drug Stability Test Chamber ADDST-503 is used in pharmaceutical laboratories for stability testing, failure analysis, and GMP-compliant long-term trials. 

ALLSENSTM Software

Portable Printer 

1 unit

LCD Touch Screen Controller

1 unit

Power Supply Interface

1 unit

Air Interface

1 unit

Partition Illuminator 

1 unit

Frequently Asked Questions of Drug Stability Test Chamber ADDST-503

1. What is a Drug Stability Test Chamber?

A Drug Stability Test Chamber is a specialized equipment used in pharmaceutical settings to test the stability of products. These units simulate a range of temperature, humidity, and light conditions to accelerate the aging process of drugs. The system is designed to meet industry standards such as Good Manufacturing Practices and is used for accelerated testing.

2. What safety features are included in the Drug Stability Test Chamber?

The Drug Stability Test Chamber is equipped with multiple safety features to protect both the samples and the system. These include over-temperature protection, humidity limit alarms, audio-visual alerts, and automatic shutoff. Drug Stability Test Chamber includes door open alarms and password-protected controls to prevent unauthorized access.

3. Can the Drug Stability Test Chamber be used for accelerated stability testing?

Yes, the Drug Stability Test Chamber is designed to carry out accelerated stability testing by using elevated temperature and humidity conditions. This type of testing helps predict the shelf life of the drug in a shorter period. It used the environmental stress that might occur during transportation. They help in manufacturing determine how long a drug will remain effective under normal storage conditions.

4. What is the role of forced convection in a Drug Stability Test Chamber?

Forced convection refers to the circulation of air within the Drug Stability Test Chamber, which helps maintain uniform temperature and humidity. This airflow ensures that all samples are exposed to the same controlled environmental conditions. It is improving the accuracy and reproducibility of stability tests. The temperature gradients prevent, which might otherwise skew test results.

5. What is the primary function of the Drug Stability Test Chamber?

The Drug Stability Test Chamber is specifically engineered for use in pharmaceutical laboratories where environmental conditions control. Its primary function is to simulate long-term, intermediate, and accelerated storage conditions in accordance with regulatory standards. This system is ideal for stability testing, failure analysis, and product shelf-life studies, making it a part of pharmaceutical and quality assurance workflows.

Similar Products of Drug Stability Test Chamber

Temperature Range 10 to 65℃ (with lighting), 0 to 60℃ (without lighting)
Humidity Range 40 to 95% RH
Illumination Range 0 to 6000LX (five stages adjustable)

USD 9,700.00

Temperature Range 10 to 65℃ (with lighting)
0 to 60℃ (without lighting)
Humidity Range 40 to 95% RH
Illumination Range 0 to 6000LX (five stages adjustable)

USD 13,390.00

Temperature Range 10 to 65℃ (with lighting), 0 to 60℃ (without lighting)
Humidity Range 40 to 95%RH
Illumination Range 0 to 6000LX (five stages adjustable)

USD 8,700.00

Temperature Range 0 to 70℃
Temperature Resolution 0.1℃
Temperature Uniformity ≤0.5℃

USD 7,520.00

Drug Test Chamber

Drug Test Chamber ADTC-507
Capacity:150 L
Temperature Range:10 °C to 65 °C
Fluctuation:± 0.5 °C
Drug Test Chamber ADTC-509
Capacity:400 L
Temperature Range:10 °C to 65 °C
Fluctuation:± 0.5 °C
Drug Test Chamber ADTC-508
Capacity:250 L
Temperature Range:10 °C to 65 °C
Fluctuation:± 0.5 °C

Climate Chamber

Climate Chamber ADCR-505
Capacity:800 L
Temperature Range:With Light 10 °C to 55°C Without Light 5 °C to 55°C
Uniformity:≤± 1 °C
Climate Chamber ADCR-503
Capacity:375 L
Temperature Range:With Light 10 °C to 55°C Without Light 5 °C to 55°C
Uniformity:≤± 1 °C
Climate Chamber ADCR-502
Capacity:275 L
Temperature Range:With Light 10 °C to 55°C Without Light 5 °C to 55°C
Uniformity:≤± 1 °C
Climate Chamber ADCR-501
Capacity:175 L
Temperature Range:With Light 10 °C to 55°C Without Light 5 °C to 55°C
Uniformity:≤± 1 °C
Climate Chamber ADCR-506
Capacity:1075 L
Temperature Range:With Light 10 °C to 55°C Without Light 5 °C to 55°C
Uniformity:≤± 1 °C
Climate Chamber ADCR-504
Capacity:475 L
Temperature Range:With Light 10 °C to 55°C Without Light 5 °C to 55°C
Uniformity:≤± 1 °C

Humidity Chamber

Humidity Chamber ADHI-502
Capacity:150 L
Temperature Range:With Humidification 0 °C to 65°C No Humidification 10 °C to 65°C
Uniformity:± 1 °C
Humidity Chamber ADHI-503
Capacity:250 L
Temperature Range:With Humidification 0 °C to 65°C No Humidification 10 °C to 65°C
Uniformity:± 1 °C
Humidity Chamber ADHI-501
Capacity:70 L
Temperature Range:With Humidification 0 °C to 65°C No Humidification 10 °C to 65°C
Uniformity:± 1 °C

Illumination Chamber

Illumination Chamber ADIR-504
Capacity:500 L
Temperature Range:10 °C to 50 °C
Uniformity:± 1 °C
Illumination Chamber ADIR-505
Capacity:1000 L
Temperature Range:10 °C to 50 °C
Uniformity:± 1 °C
Illumination Chamber ADIR-502
Capacity:260 L
Temperature Range:10 °C to 50 °C
Uniformity:± 1 °C
Illumination Chamber ADIR-501
Capacity:150 L
Temperature Range:10 °C to 50 °C
Uniformity:± 1 °C
Illumination Chamber ADIR-503
Capacity:300 L
Temperature Range:10 °C to 50 °C
Uniformity:± 1 °C

Salt Spray Test Chamber

Salt Spray Test Chamber ADST-502
Brine Tank Capacity:25L
Lab Volume:270L
Test Equipment Temperature Range:RT to 55℃

USD 2,060.00

Salt Spray Test Chamber ADST-503
Lab Volume:800L
Brine Tank Capacity:40L
Spray Pressure:1.00 ± 0.1kgf/cm2

USD 5,550.00

Salt Spray Test Chamber ADST-504
Lab Volume:1440L
Brine Tank Capacity:40L
Spray Pressure:1.00 ±0.1kgf/cm2

USD 7,260.00

Salt Spray Test Chamber ADST-501
Brine Tank Capacity:15L
Lab Volume:108L
Test Equipment Temperature Range:RT to 55℃

USD 1,520.00