| Lab Volume | 108L |
| Test Equipment Temperature Range | RT +10 ℃ to 55 ℃ |
| Pressure Tank Temperature Range | 47 ℃ ±1 ℃ / CASS: 63 ℃ ±1 ℃ |
| Temperature Fluctuations | ≤ ±0.5 ℃ |
| Temperature Uniformity | ≤ ±2 ℃ |
| Temperature Precision | ±1 ℃ |
| Spray Pressure | 1.00 ±0.01 kgf/cm² |
| Lab Relative Humidity | ≥93% RH |
| Spray Quantity | 1.0 – 2.0 ml/80 cm²/hour |
| Power Supply | AC 220 V, 50 Hz |
| Test Space (W × H × D) | 600 × 450 × 400 mm |
| External Dimension (W × H × D) | 1070 × 600 × 1180 mm |
| Weight | ~90 –100 kg |
The Salt Spray Test Chamber ADST-501 is used for testing the corrosion resistance of coatings, metals, and finished products. It is ideal for automotive, aerospace, electronics, and surface treatment industries.
| Lab Volume | 800L |
| Brine Tank Capacity | 40L |
| Spray Pressure | 1.00 ± 0.1kgf/cm2 |
| Brine Tank Capacity | 25L |
| Lab Volume | 270L |
| Test Equipment Temperature Range | RT to 55℃ |
| Lab Volume | 1440L |
| Brine Tank Capacity | 40L |
| Spray Pressure | 1.00 ±0.1kgf/cm2 |
| Capacity: | 250 L |
| Temperature Range: | 10 °C to 65 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 400 L |
| Temperature Range: | 10 °C to 65 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 150 L |
| Temperature Range: | 10 °C to 65 °C |
| Fluctuation: | ± 0.5 °C |
| Capacity: | 175 L |
| Temperature Range with Light: | 10 to 55℃ |
| Temperature Range without Light: | 0 to 55℃ |
| Capacity: | 800 L |
| Temperature Range: | With Light 10 °C to 55°C Without Light 5 °C to 55°C |
| Uniformity: | ≤± 1 °C |
| Capacity: | 475 L |
| Temperature Range: | With Light 10 °C to 55°C Without Light 5 °C to 55°C |
| Uniformity: | ≤± 1 °C |
| Capacity: | 275 L |
| Temperature Range with Light: | 10 to 55℃ |
| Temperature Range without Light: | 0 to 55℃ |
| Capacity: | 1075 L |
| Temperature Range: | With Light 10 °C to 55°C Without Light 5 °C to 55°C |
| Uniformity: | ≤± 1 °C |
| Capacity: | 375 L |
| Temperature Range: | With Light 10 °C to 55°C Without Light 5 °C to 55°C |
| Uniformity: | ≤± 1 °C |
| Capacity: | 70 L |
| Temperature Range: | With Humidification 0 °C to 65°CNo Humidification 10 °C to 65°C |
| Uniformity: | ± 1 °C |
| Capacity: | 250 L |
| Temperature Range: | With Humidification 0 °C to 65°C No Humidification 10 °C to 65°C |
| Uniformity: | ± 1 °C |
| Capacity: | 150 L |
| Temperature Range: | With Humidification 0 °C to 65°CNo Humidification 10 °C to 65°C |
| Uniformity: | ± 1 °C |
| Capacity: | 150 L |
| Temperature Range: | 10 °C to 50 °C |
| Uniformity: | ± 1 °C |
| Capacity: | 260 L |
| Temperature Range: | 10 °C to 50 °C |
| Uniformity: | ± 1 °C |
| Capacity: | 500 L |
| Temperature Range: | 10 °C to 50 °C |
| Uniformity: | ± 1 °C |
| Capacity: | 1000 L |
| Temperature Range: | 10 °C to 50 °C |
| Uniformity: | ± 1 °C |
| Capacity: | 300 L |
| Temperature Range: | 10 °C to 50 °C |
| Uniformity: | ± 1 °C |
| Temperature Range: | 10 to 65℃ (with lighting) <br/> 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95% RH |
| Illumination Range: | 0 to 6000LX (five stages adjustable) |
| Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
| Humidity Range : | 40 to 95% RH |
| Illumination Range : | 0 to 6000LX (five stages adjustable) |
| Temperature Range: | 10 to 65℃ (with lighting), 0 to 60℃ (without lighting) |
| Humidity Range: | 40 to 95%RH |
| Illumination Range: | 0 to 6000LX (five stages adjustable) |
| Temperature Range: | 0 to 70℃ |
| Temperature Resolution: | 0.1℃ |
| Temperature Uniformity: | ≤0.5℃ |
| Temperature Range: | 0 to 65℃ |
| Humidity Range: | 40 to 95% RH |
| Temperature Accuracy: | ±0.1℃ |
| Temperature Range: | 0 to 65℃ |
| Humidity Range: | 40 to 95% RH |
| Temperature Accuracy: | ±0.1℃ |
| Temperature Range: | 0 to 65℃ |
| Humidity Range: | 40 to 95% RH |
| Temperature Accuracy: | ±0.1℃ |