| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT+5℃ to 100℃ |
| Temperature Accuracy | ≤ ± 0.3℃ |
| Temperature Uniformity | ≤ ± 0.3℃ |
| Heating Time | ≤ 20min (from 40℃ to100℃) |
| Timing Range | 1sec to 99min59sec/∞ |
| Display Accuracy | 0.1℃ |
| Display | LED |
| Power Consumption | 100W |
| Power Requirement | DC 24V / 1.67A, 40W |
| Dimension (W × D × H) | 145 × 113× 110 mm |
| Weight | 0.5 kg |
Dry Bath Incubator ADDB-502 is widely used for sample preservation and reaction, as well as DNA amplification. It also supports initial denaturation in electrophoresis and other related processes.
Block No. Description Quantity Block 01 15 × 2.0 ml 1 Pc Block 02 15 × 1.5 ml 1 Pc Block 03 24 × 0.5 ml 1 Pc Block 04 32 × 0.2ml (for 0.2ml PCR 8-tube strip) 1 Pc Block 05 32 × 0.2ml (for 0.2ml Elisa 8-well strip) 1 Pc
1. What is the temperature setting range of the Dry Bath Incubator ADDB-502?
Dry Bath Incubator ADDB-502 offers a versatile temperature setting range starting from 5°C up to 100°C. This range allows it to accommodate a wide variety of laboratory applications, from gentle warming to precise heating tasks. It has advanced PID fuzzy control ensures stable and accurate temperature regulation throughout this range. This makes unit suitable for processes such as DNA amplification, enzyme reactions, and sample preservation.
2. What are the power requirements for the Dry Bath Incubator ADDB-502?
Dry Bath Incubator ADDB-502 on a DC 24V power supply with a current of 1.67A, consuming approximately 40W of power. This low power requirement makes it energy-efficient and suitable for various laboratory environments. Its design supports stable operation while minimizing electricity usage. The compact power setup also contributes to its portability and ease of use.
3. What is the heating rate of Dry Bath Incubator ADDB-502?
Dry Bath Incubator ADDB-502 features a rapid heating rate, capable of reaching the target temperature efficiently. It can heat from 40°C up to 100°C in 20 minutes or less, making it suitable for time-sensitive laboratory procedures. This fast-heating performance helps save valuable time during experiments. Combined with precise temperature control, it ensures reliable and consistent results.
4. How accurate is the temperature control of the Dry Bath Incubator ADDB-502?
Dry Bath Incubator ADDB-502 offers highly accurate temperature control with minimal fluctuation. It has PID fuzzy control technology that maintains stability, usually within ±0.3°C. This precision is essential for sensitive experiments requiring exact temperature conditions. Reliable temperature consistency helps improve reproducibility in lab work.
5. What kind of maintenance does the Dry Bath Incubator ADDB-502 require?
In Dry Bath Incubator ADDB-502 regular cleaning of the heating block and surrounding surfaces is recommended to ensure longevity. Avoid using compressed air or water on hot surfaces and allow the unit to cool naturally. Always unplug the system before maintenance. Proper care ensures consistent performance and extends the lifespan of Dry Bath Incubator.
6. What is a Dry Bath Incubator?
A Dry Bath Incubator is a laboratory instrument designed to regulate and maintain a stable temperature for samples, eliminating the need for water. It is commonly used for heating, growing, or storing biological or chemical samples under controlled conditions. Its precise temperature control makes it ideal for applications such as enzyme reactions, DNA denaturation, and sample incubation.
7. Can a Dry Bath Incubator be used for cell culture?
A Dry Bath Incubator is not suitable for cell culture, as it lacks the ability to control humidity and CO? levels, which are essential for proper cell growth. It is designed for molecular biology applications like PCR or enzyme reactions. For cell culture, a CO? incubator with precise environmental control is more appropriate. These incubators also maintain optimal temperature, pH, and gas conditions crucial for maintaining cell viability.
8. How do I ensure even heating in a Dry Bath Incubator?
To ensure even heating in a Dry Bath Incubator, always use the appropriate block size for your sample containers. Make sure the block is correctly positioned and seated within the incubator. Regularly calibrating the incubator ensures accurate temperature readings. Avoid overcrowding to allow for uniform heat distribution, and ensure the incubator door remains closed during operation to maintain stable conditions.
9. What are the typical features of a Dry Bath Incubator?
Features of a Dry Bath Incubator: • Digital temperature control: Allows for precise adjustments and displays the current temperature. • Timer function: Allows users to set incubation times. • Multiple blocks: Our incubators offer interchangeable blocks to accommodate different sample sizes. • Over-temperature alarm: Alerts users if the temperature exceeds the set point.
| Temperature Range | RT. 5℃ to 160℃ |
| Temperature Accuracy |
± 0.5℃ at 40℃ ± 1℃ at 120℃ |
| Temperature Uniformity | 1 |
| Temperature Range | RT+5℃ to 100℃ |
| Temperature Accuracy | ±0.3℃ |
| Temperature Set Range | 0℃ to 100℃ |
| Temperature Range | RT + 5℃ to 150℃ |
| Heating Up Rate |
≤ 10 min, 20℃ to 100℃ ≤ 30 min, 20℃ to 150℃ |
| Temperature Stability |
±0.3℃ at 40℃ ±0.5℃ at 100℃ ±1℃ at 120℃ |
| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT +5℃ to 100℃ |
| Temperature Accuracy | ≤ ± 0.3℃ at 37℃ |
| Temperature Setting Range: | -10℃ to 100℃ |
| Temperature Control Range: | RT -25℃ to 100℃ |
| Temperature Accuracy: | ≤ ± 0.3℃ at 37℃ |
| Block Temperature Setting Range: | RT +5℃ to 105℃ |
| Temperature Set Range: | 0℃ to 105℃ |
| Lid Temperature Setting Range: | RT +5°C to 110°C |
| Block Temperature Setting Range: | RT -30°C to 105°C |
| Temperature Set Range: | -10°C to 105°C |
| Lid Temperature Setting Range: | RT +5°C to 110°C |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT +5℃ to 100℃ |
| Temperature Accuracy: | ≤ ± 0.3℃ at 37℃ |
| Temperature Range: | RT+5℃ to 100℃ |
| Temperature Accuracy: | ±0.3℃ |
| Temperature Set Range: | 0℃ to100℃ |