| Temperature Setting Range | 0℃ to 100℃ |
| Temperature Control Range | RT +5℃ to 100℃ |
| Temperature Accuracy | ≤ ± 0.3℃ at 37℃ |
| Temperature Uniformity | ≤ ± 0.3℃ at 37℃ |
| Display Accuracy | 0.1℃ |
| Heating Time | ≤ 12min (from 25℃ to 100℃) |
| Timing Range | 1min to 99h59min / infinite |
| Heating Lid Temperature Setting Range | OFF to +10℃ |
| Heating Lid Temperature Accuracy | ≤ ± 0.5℃ |
| Heating Lid Heating Time | ≤ 10min (from 25℃ to 100℃) |
| Multi-point Running | Yes (maximum 5 points) |
| Multi Cycle | Yes (maximum 99 times) |
| Auto Running | Yes |
| Auto Resume to Run | Yes |
| Auto Heating | Yes |
| Power Requirements | AC 220V or 100V, 50 to 60 Hz, 150 W |
| Fuse | 250V 3A Ф 5×20 |
| Dimension (W × D × H) | 300 x 200 x 210 mm |
| Net Weight | 4.0 kg |
Heated Lid Dry Bath Incubator ADHDB-504 is used for precise temperature-controlled incubation of biological samples. It is ideal for labs working with tubes, plates, or PCR protocols.
| Block No. | Description
| Temperature Range | Quantity |
| Block 01 (Heating and Cooling) | 35 × 2.0 ml centrifuge tube
| RT -25℃ to 100℃ | 1 Pc |
| Block 02 (Heating and Cooling) | 35 × 1.5 ml centrifuge tube
| RT -25℃ to 100℃ | 1 Pc |
| Block 03 (Heating and Cooling) | 54 × 0.5 ml centrifuge tube
| RT -25℃ to 100℃ | 1 Pc |
| Block 04 (Heating and Cooling) | 96 × 2.0 ml PCR centrifuge tube
| RT -25℃ to 100℃ | 1 Pc |
| Block 05 (Heating and Cooling) | 96 × 0.2 ml ELISA plate
| RT -25℃ to 100℃ | 1 Pc |
| Block 06 (Heating and Cooling) | 35 × 2.0 ml centrifuge tube
| RT +5℃ to 100℃ | 1 Pc |
| Block 07 (Heating and Cooling) | 35 × 1.5 ml centrifuge tube
| RT +5℃ to 100℃ | 1 Pc |
| Block 08 (Heating and Cooling) | 54 × 0.5 ml centrifuge tube
| RT +5℃ to 100℃ | 1 Pc |
| Block 09 (Heating and Cooling) | 96 × 0.2 ml PCR centrifuge tube
| RT +5℃ to 100℃ | 1 Pc |
| Block 10 (Heating and Cooling) | 96 × 0.2 ml ELISA plate
| RT +5℃ to 100℃ | 1 Pc |
1. How does Heated Lid Dry Bath Incubator ADHDB-504 maintain temperature accuracy?
Heated Lid Dry Bath Incubator ADHDB-504 maintains temperature accuracy using advanced semiconductor technology for efficient heating and cooling. It is equipped with a PID (Proportional-Integral-Derivative) control system that constantly monitors and adjusts the temperature. This system ensures minimal fluctuations and high thermal stability during operation. As a result, samples are incubated under consistent and reliable temperature conditions.
2. Does the Heated Lid Dry Bath Incubator ADHDB-504 support programming for complex protocols?
Heated Lid Dry Bath Incubator ADHDB-504 supports programming for complex protocols through its multi-step and multi-cycle functionality. Users can set different temperature points and durations for each step within a single run. This feature is ideal for experiments requiring gradual temperature changes or repeated thermal cycles. It enhances flexibility and automation in laboratory workflows.
3. What is the purpose of the heated lid in Heated Lid Dry Bath Incubator ADHDB-504?
Heated lid in Heated Lid Dry Bath Incubator ADHDB-504 is used to prevent condensation from forming on the tops of tubes or plates during incubation. By maintaining a temperature slightly above the block, it keeps samples from evaporating or drying out. This ensures consistent sample volume and reaction conditions. It’s especially important for small volumes and sensitive experiments like PCR.
4. Is there built-in protection against overheating in Heated Lid Dry Bath Incubator ADHDB-504?
Heated Lid Dry Bath Incubator ADHDB-504 includes a built-in over-temperature protection that automatically shuts off the heating element if temperatures exceed safe limits. This safety feature prevents damage to samples and the instrument itself. It provides peace of mind by ensuring the incubator operates within a controlled temperature range. The protection system enhances the reliability and longevity of the device in daily laboratory use.
5. Does the Heated Lid Dry Bath Incubator ADHDB-504 have an auto-restart feature after a power failure?
Heated Lid Dry Bath Incubator ADHDB-504 is equipped with an auto-restart function that automatically resumes operation with the previous settings once power is restored. This ensures continuous incubation without manual intervention, preventing disruption of time-sensitive experiments. It helps maintain consistency and protects samples from temperature fluctuations caused by unexpected outages. This feature is especially useful in laboratories where stable conditions are critical.
6. What is a Heated Lid Dry Bath Incubator?
A Heated Lid Dry Bath Incubator is a laboratory instrument designed to maintain precise temperatures for samples in vials, tubes, or other containers. It uses a heated lid to ensure consistent, uniform temperature distribution. Unlike water-based baths, this type of incubator operates without liquids, preventing contamination and the risk of spills.
7. How does the Heated Lid Dry Bath Incubator work?
The Heated Lid Dry Bath Incubator works by using a heating system within the lid and sometimes the base. The temperature is controlled to provide a consistent environment for samples. The heated lid ensures that the top portion of the samples remains heated, reducing the risk of condensation or temperature gradients. This dual-heating system ensures uniform temperature distribution, improving the accuracy and reliable results.
8. What are the advantages of using a Heated Lid Dry Bath Incubator?
A Heated Lid Dry Bath Incubator offers several advantages over traditional water baths or other incubation methods. One of the main benefits is the absence of liquid, which eliminates the risk of contamination, spillage, and the need for frequent cleaning associated with water baths. The heated lid ensures uniform temperature distribution, reducing temperature gradients and minimizing condensation.
9. Can I use a Heated Lid Dry Bath Incubator for different types of samples?
Yes, Heated Lid Dry Bath Incubator are versatile and can be used for a wide range of sample types, including DNA/RNA extraction, enzyme reactions, cell culture, and more. The incubator typically supports various block types to accommodate different test tubes and microplates.
10. How to clean Heated Lid Dry Bath Incubator?
To clean a Heated Lid Dry Bath Incubator, first ensure the unit is turned off and completely cooled down. Wipe the exterior and blocks with a soft cloth dampened with mild soap and water. Avoid harsh chemicals and abrasives. For stains, use a gentle disinfectant. Ensure no liquid enters the interior and let it dry before use.
| Block Temperature Setting Range | RT +5℃ to 105℃ |
| Temperature Set Range | 0℃ to 105℃ |
| Lid Temperature Setting Range | RT +5°C to 110°C |
| Temperature Range | RT+5℃ to 100℃ |
| Temperature Accuracy | ±0.3℃ |
| Temperature Set Range | 0℃ to100℃ |
| Temperature Setting Range | -10℃ to 100℃ |
| Temperature Control Range | RT -25℃ to 100℃ |
| Temperature Accuracy | ≤ ± 0.3℃ at 37℃ |
| Block Temperature Setting Range | RT -30°C to 105°C |
| Temperature Set Range | -10°C to 105°C |
| Lid Temperature Setting Range | RT +5°C to 110°C |
| Temperature Range: | RT-30℃ to 100℃ |
| Temperature Accuracy: | ±0.3°C |
| Temperature Set Range: | -10℃ to 100℃ |
| Temperature Range: | RT + 5℃ to 150℃ |
| Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
| Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
| Temperature Setting Range: | 0℃ to 110℃ |
| Temperature Control Range: | RT +5℃ to 110℃ |
| Temperature Accuracy: | ≤ ± 0.3 at 37℃ |
| Temperature Range: | RT+5℃ to 100℃ |
| Temperature Accuracy: | ±0.3℃ |
| Temperature Set Range: | 0℃ to 100℃ |
| Temperature Range: | RT + 5℃ to 150℃ |
| Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
| Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
| Temperature Range: | RT-25℃ to 100℃ |
| Temperature Accuracy: | ±0.3℃ |
| Temperature Set Range: | -10℃ to 100℃ |
| Temperature Range: | RT. 5℃ to 160℃ |
| Temperature Accuracy: | ± 0.5℃ at 40℃ <br/> ± 1℃ at 120℃ |
| Temperature Uniformity: | 1 |
| Temperature Control Range: | RT. +5℃ to 160℃ |
| Temperature Accuracy: | ± 0.5℃ at 40℃ <br/> ± 1℃ at 120℃ |
| Temperature Uniformity: | ± 0.5℃ |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT 5℃ to 100℃ |
| Temperature Accuracy: | ≤±0.3℃ |
| Temperature Range: | RT + 5℃ to 150℃ |
| Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
| Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
| Temperature Range: | RT+5°C to 100°C |
| Temperature Accuracy: | ±0.3°C |
| Temperature Set Range: | 5°C to 100°C |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT. -20℃ to 100℃ |
| Temperature Accuracy: | ≤ ± 0.3℃ |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT+5℃ to 100℃ |
| Temperature Accuracy: | ≤ ± 0.3℃ |
| Temperature Setting Range: | -10℃ to 100℃ |
| Temperature Control Range : | RT -30℃ to 100℃ |
| Temperature Accuracy: | ≤ ± 0.3℃ |
| Temperature Range: | RT. 5℃ to 130℃ |
| Temperature Accuracy: | ± 0.5℃ at 40℃ <br/> ± 1℃ at 40℃ |
| Temperature Uniformity: | ± 0.5℃ |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT +5℃ to 100℃ |
| Temperature Accuracy: | ≤ ± 0.5℃ at 37℃ |
| Temperature Range: | RT+5℃ to 105℃ |
| Temperature Accuracy: | ±0.3℃ |
| Temperature Set Range: | 0℃ to 105℃ |
| Temperature Range: | RT + 5℃ to 150℃ |
| Heating Up Rate: | ≤ 10 min, 20℃ to 100℃ <br/> ≤ 30 min, 20℃ to 150℃ |
| Temperature Stability : | ±0.3℃ at 40℃ <br/> ±0.5℃ at 100℃ <br/> ±1℃ at 120℃ |
| Temperature Setting Range: | 0℃ to 100℃ |
| Temperature Control Range: | RT +5℃ to 100℃ |
| Temperature Accuracy: | ≤ ± 0.3℃ at 37℃ |