Double Beam Spectrophotometer ADDS-516
Double Beam Spectrophotometer ADDS-516
Double Beam Spectrophotometer ADDS-516
Double Beam Spectrophotometer ADDS-516

Double Beam Spectrophotometer ADDS-516

Double Beam Spectrophotometer ADDS-516 offers ± 0.3 nm wavelength accuracy for substance identification by absorbance peaks. It includes an automatic wavelength calibration system for enhanced ease of use. The user-friendly software enables easy data processing, storage, and reporting. This unit provides high photometric accuracy and stability for reliable analytical results. Our Double Beam Spectrophotometer is used in pharmaceuticals, food analysis, and research for detection of substances. 


Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability <=0.1nm
Photometric Accuracy 0.2 % T (0 to 100 % T), ± 0.002 A (0 to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 % T), 0.00 A (0 to 0.5A), 0.002 A (0.5 to 1A)
Photometric Range 0 to 200 % T, 0.3 to 3 A, 0 to 999 C
Stray Light <=0.03 % T, 220 nm, 360 nm
Stability ± 0.0005 A/h 500 nm
Baseline Flatness ± 0.002 A
Noise 0.0005 A 500 nm
Work Mode T, A, C, E
Scanning Speed High, medium, low (Max. 3000 nm/min)
Wavelength Setting Auto
Light Source Imported Xenon Lamp
Detector Imported silicon photodiode
Cuvette Holder 10 mm single hole cell holder
Output USB drive, USB host, RS232
Power AC 110 to 220 V 50 to 60 Hz
Dimensions (L×B×H) 810×660×390 mm
Gross Weight 27 kg
  • High spectral resolution
  • User-friendly interface
  • Simultaneous dual-beam design
  • Cuvette holder options
  • Long-term stability

Our Double Beam Spectrophotometer ADDS-516 is used in clinical diagnostics, biotechnology, and agricultural research for accurate detection and quantification of various substances.

Accessory

Quantity

10 mm glass cuvette

4 Pc

10 mm quartz cuvette (UV)

2 Pc

Power cord

1 Pc

User's Manual

1 Pc

PC software

1 Pc

Double Beam Spectrophotometer ADDS-516|Noise:0.0005A 500 nm|Spectral Bandwidth:2 nm
Double Beam Spectrophotometer ADDS-516|High spectral resolution|User-friendly interface

Frequently Asked Questions of Double Beam Spectrophotometer ADDS-516

1. What is the main advantage of using the Double Beam Spectrophotometer ADDS-516 over a single beam model?

The Double Beam Spectrophotometer ADDS-516 offers simultaneous measurement of sample and reference beams, minimizing drift and improving stability. This results in more accurate and reliable absorbance data, especially for long-term experiments. The design reduces errors caused by fluctuations in the light source or detector. It ensures consistent baseline correction without needing to reset between scans. Overall, it provides greater measurement precision than single-beam instruments.

2. What wavelength range does the Double Beam Spectrophotometer ADDS-516 cover?

The Double Beam Spectrophotometer ADDS-516 typically operates in the UV-Visible range, covering approximately 190–1100 nm. This wide range allows for analysis of both UV-absorbing and visible-light absorbing compounds. It supports diverse applications, from biochemical assays to material quality testing. The wavelength accuracy and repeatability make it suitable for research and quality control alike. Users can rely on consistent spectral output across the full range.

3. Can the Double Beam Spectrophotometer ADDS-516 be used for kinetic studies or time-based measurements?

Yes, the Double Beam Spectrophotometer ADDS-516 is capable of conducting kinetic studies by monitoring changes in absorbance over time. It can be programmed to take readings at set intervals, making it ideal for enzyme reactions or chemical kinetics. The instrument ensures stability during extended use due to its double-beam design. Users can observe reaction progress in real-time with high sensitivity. This function is particularly useful in biological and pharmaceutical research.

4. Is the Double Beam Spectrophotometer ADDS-516 user-friendly and does it come with data analysis software?

Yes, the Double Beam Spectrophotometer ADDS-516 is designed with a user-friendly interface, often featuring a touchscreen or PC connectivity with intuitive software. The included software supports functions like wavelength scanning, quantitative analysis, and data export. Users can easily store, analyze, and print results for documentation or regulatory needs. Its interface allows even non-expert users to operate it efficiently after basic training. This ease of use makes it ideal for both academic and industrial labs.

Similar Products of Dual Beam Spectrophotometer

Wavelength Range 190 to 1100 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.2 nm
Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Display 7-inch Colour Screen
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190 to 1100 nm

Visible Spectrophotometer

Visible Spectrophotometer ADVS-502
Wavelength Range:320 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm
Visible Spectrophotometer ADVS-501
Wavelength Range:325 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm

Digital Spectrophotometer

Digital Spectrophotometer ADSM-503
Wavelength Range:195 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-501
Wavelength Range:340 to 1000 nm
Wavelength Accuracy:± 3 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-502
Wavelength Range:325 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9

Single Beam UV-Vis Spectrophotometer

Single Beam UV-Vis Spectrophotometer ADSS-522
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-501
Sample Volume:0.5 to 2.0 μL
Nucleic Acid Detection Range:2 to 15000 ng/μL (dsDNA) <br/> 1.32 to 9900 ng/μL (ss DNA) <br/> 1.6 to12000ng/μL (RNA)
Protein Detection Range:0.04 to 750 mg/mL (A280) <br/> 0.06 to 1119 mg/mL (BSA) <br/> 0.03 to 547 mg/mL (IgG) <br/> 0.015 to 284 mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-510
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-511
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-505
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-507
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-525
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-512
Series:K Series Touch Screen
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190–1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-527
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-517
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-520
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-515
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-502
Sample Volume:0.5μl to 2μl (recommended to use 2μl)
Nucleic Acid Detection Range:2 to 37500ng /μL (dsDNA) <br/> 1.32 to 24750 ng/μL (ss DNA) <br/> 1.6 to 30000ng/μL (RNA)
Protein Detection Range:0.04 to 750mg/mL (A280) <br/> 0.06 to 1119mg/mL (BSA) <br/> 0.03 to 547mg/mL (IgG) <br/> 0.015 to 284mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-508
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-514
Series:K Series Color Screen
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190–1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-518
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-513
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-506
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/ 2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-526
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-523
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-509
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/2/4
Single Beam UV-Vis Spectrophotometer ADSS-504
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-503
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:320 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-516
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-524
Series:K Series Color Screen
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190–1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-521
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-519
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm

Split Beam Spectrophotometer

Split Beam Spectrophotometer ADSBS-501
Optical System:Split Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer ADFS-A100
Excitation Source:150 W Xenon Lamp, Long-Life Hamamatsu
Excitation Wavelength:200–900 nm
Emission Wavelength:200–900 nm