Double Beam Spectrophotometer ADDS-512
Double Beam Spectrophotometer ADDS-512
Double Beam Spectrophotometer ADDS-512
Double Beam Spectrophotometer ADDS-512

Double Beam Spectrophotometer ADDS-512

Double Beam Spectrophotometer ADDS-512 offers ± 0.1 nm wavelength accuracy for substance identification by absorbance peaks. The double-beam design corrects light source fluctuations in real time for reliable measurements. It uses dual light paths to measure sample and reference simultaneously for high accuracy. This unit covers a broad wavelength range for UV and visible analysis. Our Double Beam Spectrophotometer is used in pharmaceuticals, academic research, and chemical analysis for analysing the light absorption.


Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1 nm 656.1 nm, ± 0.3 nm all
Wavelength Repeatability <=0.1 nm
Photometric Accuracy 0.2 % T (0 to 100 % T), ± 0.002 A (0 to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 % T), 0.00 A (0 to 0.5 A), 0.002 A (0.5 to 1 A)
Photometric Range 0 to 200 % T, 0.3 to 3 A, 0 to 999 C
Stray Light <=0.03 % T, 220 nm, 360 nm
Stability ± 0.0003 A/h 500 nm
Baseline Flatness ± 0.001 A
Noise 0.0005 A 500 nm
Work Mode T, A, C, E
Scanning Speed High, medium, low (Max. 3000 nm/min)
Display 10.1 inches Colour touch screen
Light Source Deuterium and tungsten lamp
Detector Imported silicon photodiode
Cuvette Holder 10 mm Single hole cell holder
Output USB drive, USB host, RS232
Power AC 110 to 220 V 50 to 60 Hz
Dimensions (L×B×H) 880×690×520 mm
Gross Weight 45 kg
  • Single optical path design
  • Lamp source options
  • Quantitative analysis modes
  • High photometric accuracy
  • Adjustable bandwidth

Our Double Beam Spectrophotometer ADDS-512 is used in quality control, research, and clinical labs for precise analysis of absorbance and concentration.

Accessory

Quantity

10 mm glass cuvette

4 Pc

10 mm quartz cuvette (UV)

2 Pc

Power cord

1 Pc

User's Manual

1 Pc

PC software

1 Pc

Frequently Asked Questions of Double Beam Spectrophotometer ADDS-512

1. What is the main advantage of using the Double Beam Spectrophotometer ADDS-512?

The Double Beam Spectrophotometer ADDS-512 provides simultaneous measurement of sample and reference, offering higher accuracy and stability in absorbance readings. This design helps in reducing drift and compensating for fluctuations in the light source. It ensures real-time comparison, enhancing reliability for long-duration experiments. Users benefit from improved baseline correction and minimal noise. Overall, it is ideal for precise quantitative analysis in research and industrial labs.

2. What wavelength range does the Double Beam Spectrophotometer ADDS-512 cover?

The Double Beam Spectrophotometer ADDS-512 typically covers a broad wavelength range from 190 nm to 1100 nm. This allows it to analyze a wide variety of samples, from UV to visible light. It is especially suitable for compounds that absorb in both UV and visible regions. The broad range supports diverse applications in chemistry, biology, and environmental testing. With high-resolution optics, it delivers sharp spectral details across the entire range.

3. Is the Double Beam Spectrophotometer ADDS-512 suitable for kinetic studies or time-based measurements?

Yes, the Double Beam Spectrophotometer ADDS-512 is well-suited for kinetic studies and real-time monitoring of reactions. Its fast scanning and stable beam design allow accurate tracking of absorbance changes over time. The software typically includes kinetic modes with adjustable time intervals. This makes it effective for enzyme studies, reaction rate analysis, and thermal denaturation experiments. Users can record and analyze data efficiently with built-in data processing tools.

4. What types of samples can be analyzed with the Double Beam Spectrophotometer ADDS-512?

The Double Beam Spectrophotometer ADDS-512 can analyze a wide range of liquid samples, and with proper accessories, it can also handle solid and film samples. It supports different cuvette sizes and path lengths to accommodate varied sample types. Whether for quantitative or qualitative analysis, it performs reliably across industries like pharmaceuticals, food testing, and water quality monitoring. It is especially effective for solutions requiring high sensitivity and accuracy. Compatibility with flow cells and temperature control enhances its application versatility.

5. Does the Double Beam Spectrophotometer ADDS-512 offer data storage and connectivity features?

Yes, the Double Beam Spectrophotometer ADDS-512 often includes USB ports, PC connectivity, and internal memory for convenient data storage and transfer. The user can save, export, and analyze data using software on an external computer. This enables better report generation, remote monitoring, and integration into laboratory information systems (LIMS). Some models also offer SD card support or printer connectivity. These features streamline workflow and ensure data traceability.

Similar Products of Dual Beam Spectrophotometer

Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Wavelength Range 190 to 1100 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.2 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1 nm
Optical System Single beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 2 nm

Visible Spectrophotometer

Visible Spectrophotometer ADVS-501
Wavelength Range:325 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm
Visible Spectrophotometer ADVS-502
Wavelength Range:320 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm

Digital Spectrophotometer

Digital Spectrophotometer ADSM-501
Wavelength Range:340 to 1000 nm
Wavelength Accuracy:± 3 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-502
Wavelength Range:325 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-503
Wavelength Range:195 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9

Single Beam UV-Vis Spectrophotometer

Single Beam UV-Vis Spectrophotometer ADSS-506
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/ 2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-524
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-521
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-520
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-510
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-526
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-516
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-523
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-504
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-507
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-515
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-517
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-502
Sample Volume:0.5μl to 2μl (recommended to use 2μl)
Nucleic Acid Detection Range:2 to 37500ng /μL (dsDNA) <br/> 1.32 to 24750 ng/μL (ss DNA) <br/> 1.6 to 30000ng/μL (RNA)
Protein Detection Range:0.04 to 750mg/mL (A280) <br/> 0.06 to 1119mg/mL (BSA) <br/> 0.03 to 547mg/mL (IgG) <br/> 0.015 to 284mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-511
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-518
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-501
Sample Volume:0.5 to 2.0 μL
Nucleic Acid Detection Range:2 to 15000 ng/μL (dsDNA) <br/> 1.32 to 9900 ng/μL (ss DNA) <br/> 1.6 to12000ng/μL (RNA)
Protein Detection Range:0.04 to 750 mg/mL (A280) <br/> 0.06 to 1119 mg/mL (BSA) <br/> 0.03 to 547 mg/mL (IgG) <br/> 0.015 to 284 mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-522
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-509
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/2/4
Single Beam UV-Vis Spectrophotometer ADSS-512
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-503
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:320 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-519
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-508
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-527
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-514
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-505
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-525
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-513
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm

Split Beam Spectrophotometer

Split Beam Spectrophotometer ADSBS-501
Optical System:Split Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm