Double Beam Spectrophotometer ADDS-521 offers ± 656.1 nm wavelength accuracy for substance identification by absorbance peaks. It uses dual light paths to measure sample and reference simultaneously for high accuracy. This unit covers a broad wavelength range for UV and visible analysis. The double-beam design corrects light source fluctuations in real time for reliable measurements. Our Double Beam Spectrophotometer is used in pharmaceuticals, academic research, and chemical analysis for analysing the light absorption.


Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm 656.1 nm, ± 0.3 nm all
Wavelength Repeatability <=0.1 nm
Photometric Accuracy 0.2 % T (0 to 100 % T), ± 0.002 A (0 to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 % T), 0.00 A (0 to 0.5 A), 0.002 A (0.5 to 1 A)
Photometric Range 0 to 200 % T, 0.3 to 3 A, 0 to 999 C
Stray Light <=0.03 % T, 220 nm, 360 nm
Stability ± 0.0005 A/h 500 nm
Baseline Flatness ± 0.001 A
Noise 0.0005 A 500 nm
Work Mode T, A, C, E
Scanning Speed High, medium, low (Max. 3000 nm/min)
Wavelength Setting Auto
Light Source Deuterium and tungsten lamp
Detector Imported silicon photodiode
Cuvette Holder 10 mm Single-hole cell holder
Output USB drive, USB host, RS232
Power AC 110 to 220 V 50 to 60 Hz
Dimensions (L×B×H) 810×660×390 mm
Gross Weight 27 kg
  • Quantitative analysis modes 
  • Lamp source options
  • Adjustable bandwidth
  • Single optical path design
  • High photometric accuracy

Our Double Beam Spectrophotometer ADDS-521 is used in clinical diagnostics, academic research, and water quality monitoring, for accurate chemical and optical measurements.

Accessory

Quantity

10 mm glass cuvette

4 Pc

10 mm quartz cuvette (UV)

2 Pc

Power cord

1 Pc

User's Manual

1 Pc

PC software

1 Pc

Double Beam Spectrophotometer ADDS-521|Spectral Bandwidth:1 nm|Noise:0.0005 A 500 nm
Double Beam Spectrophotometer ADDS-521|Quantitative analysis modes |Lamp source options

Frequently Asked Questions of Double Beam Spectrophotometer ADDS-521

1. How should the Double Beam Spectrophotometer ADDS-521 be maintained for optimal performance?

To maintain accuracy, the instrument should be calibrated regularly and kept in a dust-free, dry environment. The sample compartment should be cleaned frequently, and the optical components should not be touched with bare hands. Software updates and regular performance checks are also recommended. Lamp life should be monitored and replaced when nearing end-of-life. Proper maintenance extends the device's lifespan and ensures consistent results.

2. What are the key features of the Double Beam Spectrophotometer ADDS-521?

The Double Beam Spectrophotometer ADDS-521 features a wide wavelength range, high photometric accuracy, real-time beam comparison, and user-friendly software. Its optical system ensures stable and reproducible results. It often includes a touchscreen interface and options for data export. The double beam setup allows long-term measurements without frequent recalibration. These features support reliable, high-throughput analysis in professional lab settings.

3. How does the Double Beam Spectrophotometer ADDS-521 differ from a single beam spectrophotometer?

Unlike single beam models, the Double Beam Spectrophotometer ADDS-521 simultaneously measures both sample and reference beams, reducing measurement drift. This real-time comparison compensates for lamp intensity variations and enhances stability. It is more suitable for kinetic studies and high-precision work. While single beam spectrophotometers are simpler and more economical, the ADDS-521 offers superior performance and reliability.

4. What are the main applications of the Double Beam Spectrophotometer ADDS-521 in different fields?

The Double Beam Spectrophotometer ADDS-521 is widely used in pharmaceutical analysis, environmental testing, chemical research, food and beverage quality control, and educational labs. It helps determine the concentration of compounds by measuring their absorbance at specific wavelengths. In environmental labs, it can assess water quality by detecting pollutants. In pharmaceuticals, it ensures active ingredient consistency in drugs. Its accuracy and versatility make it suitable for both research and routine analysis.

5. What is the working principle of the Double Beam Spectrophotometer ADDS-521?

It operates on the principle of splitting a light beam into two paths—one passing through the sample and the other through a reference. This allows simultaneous measurement of both, minimizing errors due to fluctuations in light source intensity. The instrument detects the absorbance of the sample at specific wavelengths. It compares this with the reference to provide accurate and stable readings. This dual-path design enhances precision and repeatability.

Similar Products of Dual Beam Spectrophotometer

Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/ 1/ 2/ 5 nm
Working Modes Transmittance, Absorbance, Concentration, Energy
Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Display 7-inch Colour screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1 nm

Visible Spectrophotometer

Visible Spectrophotometer ADVS-501
Wavelength Range:325 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm
Visible Spectrophotometer ADVS-502
Wavelength Range:320 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm

Digital Spectrophotometer

Digital Spectrophotometer ADSM-502
Wavelength Range:325 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-501
Wavelength Range:340 to 1000 nm
Wavelength Accuracy:± 3 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-503
Wavelength Range:195 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9

Single Beam UV-Vis Spectrophotometer

Single Beam UV-Vis Spectrophotometer ADSS-523
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-511
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-514
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-515
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-507
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-522
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-521
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-502
Sample Volume:0.5μl to 2μl (recommended to use 2μl)
Nucleic Acid Detection Range:2 to 37500ng /μL (dsDNA) <br/> 1.32 to 24750 ng/μL (ss DNA) <br/> 1.6 to 30000ng/μL (RNA)
Protein Detection Range:0.04 to 750mg/mL (A280) <br/> 0.06 to 1119mg/mL (BSA) <br/> 0.03 to 547mg/mL (IgG) <br/> 0.015 to 284mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-513
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-526
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-516
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-525
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-517
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-518
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-519
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-508
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-510
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-505
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-504
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-506
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/ 2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-509
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/2/4
Single Beam UV-Vis Spectrophotometer ADSS-527
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-524
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-501
Sample Volume:0.5 to 2.0 μL
Nucleic Acid Detection Range:2 to 15000 ng/μL (dsDNA) <br/> 1.32 to 9900 ng/μL (ss DNA) <br/> 1.6 to12000ng/μL (RNA)
Protein Detection Range:0.04 to 750 mg/mL (A280) <br/> 0.06 to 1119 mg/mL (BSA) <br/> 0.03 to 547 mg/mL (IgG) <br/> 0.015 to 284 mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-512
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-503
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:320 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-520
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm

Split Beam Spectrophotometer

Split Beam Spectrophotometer ADSBS-501
Optical System:Split Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm