Double Beam Spectrophotometer ADDS-523 analyses samples in the visible to near-infrared range from 190 to 1100 nm. It includes powerful software for spectral analysis and concentration measurement. This unit features automatic wavelength calibration to reduce errors. The system enables quantitative and qualitative analysis with versatile scanning modes. Our Double Beam Spectrophotometer is used in food quality control, research and biotechnology for analysis of sample absorbance.


Display 10.1 TFT coloured capacitive touch screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm 656.1 nm, ± 0.3 nm all
Wavelength Repeatability <=0.1nm
Photometric Accuracy 0.2 % T (0 to 100 % T), ± 0.002 A (0 to 0.5 A), ± 0.004 A (0.5 to 1 A)
Photometric Repeatability ≤0.15 % T (0 to 100 % T), 0.00 A (0 to 0.5 A), 0.002 A (0.5 to 1 A)
Photometric Range 0 to 200 % T, -0.3 to 3 A, 0 to 9999 C (0 to 9999 F)
Stray Light <=0.03 % T, 220 nm, 360 nm
Stability ± 0.0005 A/h 500nm
Baseline Flatness ± 0.001 A
Noise 0.0005 A 500 nm
Work Mode T, A, C, E
Scanning Speed High, medium, low (Max. 3000 nm/min)
Wavelength Setting Auto
Light Source Imported deuterium and tungsten lamp
Detector Imported silicon photodiode
Cuvette Holder 10 mm Single-hole cell holder
Output USB drive, USB host, RS232
Power AC 220 V/50 Hz or AC 110 V/60 Hz
Dimensions (L×B×H) 700×680×340 mm
Gross Weight 27 kg
  • Multi-cuvette holder
  • Data storage and transfer
  • User-friendly interface
  • Automatic wavelength scanning
  • Reduces baseline drift

Our Double Beam Spectrophotometer ADDS-523 is used in forensic analysis, agricultural research and cosmetics quality control for precise optical and chemical analysis.

Accessory

Quantity

10 mm glass cuvette

4 Pc

10 mm quartz cuvette (UV)

2 Pc

Power cord

1 Pc

User's Manual

1 Pc

PC software

1 Pc

Double Beam Spectrophotometer ADDS-523(Spectral Bandwidth:2 nm|Noise:0.0005 A 500 nm
Double Beam Spectrophotometer ADDS-523(Multi-cuvette holder|Data storage and transfer

Frequently Asked Questions of Double Beam Spectrophotometer ADDS-523

1. What is the wavelength range of the Double Beam Spectrophotometer ADDS-523, and why is it important?

The Double Beam Spectrophotometer ADDS-523 covers a wavelength range of 190 to 1100 nm, enabling analysis in the UV, visible, and near-infrared regions. This wide range is suitable for detecting a broad spectrum of compounds. It supports applications in biochemistry, environmental testing, pharmaceuticals, and more. Users can select wavelengths accurately for specific analytes. It enhances flexibility in various lab applications.

2. What is the main advantage of using the Double Beam Spectrophotometer ADDS-523?

The primary advantage of the Double Beam Spectrophotometer ADDS-523 is its double beam design, which allows simultaneous measurement of the sample and reference. This greatly reduces errors caused by fluctuations in the light source. It ensures higher stability and better accuracy in absorbance readings. The system continuously compensates for drift or noise. This makes it ideal for precise quantitative analysis.

3. Is the Double Beam Spectrophotometer ADDS-523 suitable for quantitative analysis?

Yes, the Double Beam Spectrophotometer ADDS-523 is designed for accurate quantitative measurements. It supports standard curve creation, multi-wavelength readings, and kinetic studies. The software enables users to input calibration data and calculate unknown concentrations easily. Its precision optics and stable baseline make it ideal for detecting small changes in absorbance. It is widely used in pharmaceutical and biochemical quantification.

4. What kind of cuvettes are compatible with the Double Beam Spectrophotometer ADDS-523?

The Double Beam Spectrophotometer ADDS-523 typically supports standard 10 mm pathlength quartz or glass cuvettes. The sample holder is designed for easy cuvette insertion and removal. Some models may support multiple cuvette sizes or flow-through options. Quartz cuvettes are ideal for UV measurements, while glass is sufficient for visible light analysis. Always ensure cuvettes are clean to maintain accuracy.

5. What maintenance does the Double Beam Spectrophotometer ADDS-523 require?

Regular maintenance includes keeping the optical path clean and ensuring the cuvettes are free of residue. The light source and detectors should be inspected periodically as per the manual. Software updates may also be necessary for optimal performance. Avoid placing the unit in dusty or humid environments. With proper care, the instrument can provide years of reliable service.

Similar Products of Dual Beam Spectrophotometer

Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Display 7-inch Colour Screen
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Display 7-inch Colour Screen
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Optical System Double beam, grating 1200 lines/mm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5/1/2/4/5 nm

Visible Spectrophotometer

Visible Spectrophotometer ADVS-502
Wavelength Range:320 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm
Visible Spectrophotometer ADVS-501
Wavelength Range:325 to 1050 nm
Wavelength Accuracy:± 2 nm
Wavelength Reproducibility:1 nm

Digital Spectrophotometer

Digital Spectrophotometer ADSM-503
Wavelength Range:195 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-502
Wavelength Range:325 to 1000 nm
Wavelength Accuracy:± 2 nm
Transmittance Range:0 to 199.9
Digital Spectrophotometer ADSM-501
Wavelength Range:340 to 1000 nm
Wavelength Accuracy:± 3 nm
Transmittance Range:0 to 199.9

Single Beam UV-Vis Spectrophotometer

Single Beam UV-Vis Spectrophotometer ADSS-514
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-506
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/ 2/4/5 nm
Single Beam UV-Vis Spectrophotometer ADSS-518
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-521
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-512
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-526
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-513
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-504
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-516
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-510
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-501
Sample Volume:0.5 to 2.0 μL
Nucleic Acid Detection Range:2 to 15000 ng/μL (dsDNA) <br/> 1.32 to 9900 ng/μL (ss DNA) <br/> 1.6 to12000ng/μL (RNA)
Protein Detection Range:0.04 to 750 mg/mL (A280) <br/> 0.06 to 1119 mg/mL (BSA) <br/> 0.03 to 547 mg/mL (IgG) <br/> 0.015 to 284 mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-522
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-505
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-519
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-507
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-527
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-524
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-515
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5nm
Single Beam UV-Vis Spectrophotometer ADSS-523
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-517
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:320 to 1100 nm
Single Beam UV-Vis Spectrophotometer ADSS-503
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:320 to 1100 nm
Spectral Bandwidth:2 nm
Single Beam UV-Vis Spectrophotometer ADSS-520
Optical System:Single beam
Monochromator:C-T Monochromator, blazed holographic grating 1200 lines/nm
Wavelength Range:190 to 1020 nm
Single Beam UV-Vis Spectrophotometer ADSS-509
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.1/0.2/0.5/1/2/4
Single Beam UV-Vis Spectrophotometer ADSS-502
Sample Volume:0.5μl to 2μl (recommended to use 2μl)
Nucleic Acid Detection Range:2 to 37500ng /μL (dsDNA) <br/> 1.32 to 24750 ng/μL (ss DNA) <br/> 1.6 to 30000ng/μL (RNA)
Protein Detection Range:0.04 to 750mg/mL (A280) <br/> 0.06 to 1119mg/mL (BSA) <br/> 0.03 to 547mg/mL (IgG) <br/> 0.015 to 284mg/mL (lysozyme)
Single Beam UV-Vis Spectrophotometer ADSS-508
Optical System:Single Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-511
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:1 nm
Single Beam UV-Vis Spectrophotometer ADSS-525
Optical System:Single beam, grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:0.5/1/2/4/5 nm

Split Beam Spectrophotometer

Split Beam Spectrophotometer ADSBS-501
Optical System:Split Beam, Grating 1200 lines/mm
Wavelength Range:190 to 1100 nm
Spectral Bandwidth:2 nm