Floor Type Freeze Dryer ADFFD-504
Floor Type Freeze Dryer ADFFD-504
Floor Type Freeze Dryer ADFFD-504
Floor Type Freeze Dryer ADFFD-504

Floor Type Freeze Dryer ADFFD-504

Floor Type Freeze Dryer ADFFD-504 features a 9.5-liter cold trap volume, allowing efficient freeze-drying of multiple samples at once. It is operated via a PLC control system with a user-friendly touch screen for enhanced ease of use. An acoustic alarm with a message display ensures real-time alerts and system monitoring. Separate valves ensure fine control and maintain sample structure. Our system is ideal for laboratory applications requiring consistent, reliable sample preservation.


Cold Trap Temperature -60℃ (below)
Freeze Drying Time 36 to 48 h
Cold Trap Volume 9.5 L
Freeze Drying Area 0.09 m²
Water Capture Capacity 4 Kg/batch
Vacuum Degree 10 Pa (below)
Vacuum Pump 2 L/s
Refrigerant R600a + R290 + R23
Shelf Quantity 3 pcs
Shelf Space 70 mm
Loading Capacity 300 ml
Total Loading Capacity 900 ml
Tray Size ф200 × 20 mm
Tray Quantity 3 pcs
Manifold 8 pcs
Vial Capacity Ø22:195 vials
Ø16:360 vials
Ø12:690
Cold Trap Size ф217 × 250 mm
Drying Chamber Dimensions ф240 (260) × 450 mm
Noise Level 66 dB (below)
Power Consumption 0.95 (to1.5) kW
Power Supply 220V/50Hz, 220V/60Hz
Main Unit packing size (W x D x H) 730 × 600 × 1180 mm
Dimension (W x D x H) 410 × 410 × 640 mm
Vacuum Pump packaging size (W x D x H) 220 × 580 × 370 mm
Overall Dimensions (W x D x H) 480 × 610 × 905 (to 1415) mm
Net Weight 70 (to 83) Kg
Gross Weight 135 (to155) Kg
  • High water capture
  • Auto data backup
  • Curve query function
  • Nitrogen gas port
  • Wide arc drying chamber

The Floor Type Freeze Dryer ADFFD-504 features self-diagnosis to monitor system status, detect issues, and allow selective control of components, ensuring high operational efficiency for laboratories, research centers, and biotech industries.

Vacuum Pump

1unit

Trays

3 unit

Drying Rack

1unit

Acrylic Cover

1unit

Acrylic Bucket

1unit

Drying Flask

8 unit

Switch Valve

8 unit

Vacuum Pump Outlet Oil Mist Filter

1unit

Vacuum Pump Inlet Dust Filter

1unit

Vacuum Pump Inlet Vapor Filter

1unit

Electric Defrosting

1unit

Shelf Heating

1unit

100ml round bottom freeze drying flask

1unit

200ml round bottom freeze drying flask

1unit

250ml round bottom freeze drying flask

1unit

600ml round bottom freeze drying flask

1unit

1000ml round bottom freeze drying flask

1unit

1200ml round bottom freeze drying flask

1unit

Floor Type Freeze Dryer ADFFD-504 | Cold Trap Temperature -60℃ (below) | Freeze Drying Time 36 to 48 h
Floor Type Freeze Dryer ADFFD-504 | High water capture | Auto data backup

Frequently Asked Questions of Floor Type Freeze Dryer ADFFD-504

1. What is the freeze-drying time of the Floor Type Freeze Dryer?

The freeze-drying time for the Floor Type Freeze Dryer typically ranges from 36 to 48 hours, depending on the specific characteristics of the sample. The time required for drying is determined by factors, including the volume of the sample, the temperature and the moisture content that needs to be removed. For more moisturize-rich samples, the process may take longer, while less complex samples can be dried more quickly.

2. How does the cold trap prevent condensation and frost in the Floor Type Freeze Dryer?

The cold trap is a crucial component in freeze-drying systems, designed to collect moisture that is sublimated from the samples. It features a heat-insulated top surface of the cold trap to prevent condensation and frost buildup. When water vapor is removed from the samples, it is directed to the cold trap, where it is rapidly frozen. Without adequate insulation, the cold trap itself could become too cold, causing condensation to form on its surface.

3. Can the Floor Type Freeze Dryer be used for sensitive biological samples?

Yes, it is specifically designed to handle sensitive biological samples that require precise preservation. Freeze-drying is one of the best methods to preserve materials because it removes moisture at very low temperatures. The controlled environment ensures that active ingredients, molecular structures, are maintained, after long-term storage. It offers control over pressure, and drying time, allowing us to optimize conditions for each unique sample.

4. What type of control system does the Floor Type Freeze Dryer use?

The Floor Type Freeze Dryer is equipped with a Programmable Logic Controller system, which is one of the most flexible control systems. The system is paired with an intuitive touch screen interface that allows users to adjust all key parameters. This includes temperature control, vacuum pressure, drying time, and critical variables. The user-friendly interface simplifies operation and ensures those with minimal technical expertise can operate the system effectively.

5. How does the self-diagnosis feature work in the Floor Type Freeze Dryer?

The self-diagnosis feature plays a vital role in monitoring the condition of the machine's key components in real-time. The system continuously checks the working status of critical parts such as the pump, cold trap, manifold, and valves. If the system detects any irregularities such as an unexpected temperature fluctuation, a malfunctioning pump. The self-diagnosis feature stores historical fault data, helping with preventive maintenance planning.

6. What are the key features of a Floor Type Freeze Dryer?

Floor Type Freeze Dryers are equipped with several key features for efficient, high-quality drying. These include large chamber capacities, which allow for processing larger sample volumes, and programmable controls. Real-time monitoring tracks key parameters like temperature and vacuum pressure, ensuring optimal drying conditions. Low-noise operation makes them suitable for continuous use in laboratory settings.

7. How does a Floor Type Freeze Dryer work?

The Floor Type Freeze Dryer works through a three-stage process. First, the sample is frozen to ultra-low temperatures, turning the water content into ice. Next, during the primary drying phase, a vacuum is applied to sublimate the ice directly into vapor, bypassing the liquid phase. In the secondary drying phase, residual moisture is removed by gradually increasing the temperature. This ensures that the sample reaches its final dry state while preserving its integrity.

8. What is a Floor Type Freeze Dryer used for?

A Floor Type Freeze Dryer is used for efficiently Freeze-Drying large volumes of sensitive materials in industries like pharmaceuticals, biotechnology, food processing, and chemicals. They preserve vaccines, enzymes, plant extracts, and other moisture-sensitive materials by removing moisture through sublimation. This process maintains the integrity, potency, and stability of the sample without altering its structure or bioactivity, making it ideal for long-term storage.

Similar Products of Floor Type Freeze Dryer

Cold Trap Temperature ≤ -60℃
Freeze Drying Time 36 to 48 h
Cold Trap Volume 28 L
Cold Trap Temperature ≤ -60℃
Freeze Drying Time 36 to 48 h
Cold Trap Volume 28 L
Temperature Range ≤–80℃
Vacuum Level < 10 Pa
Total Drying Area 0.12m²
Cold Trap Temperature -60℃ (below)
Freeze Drying Time 36 to 48 h
Cold Trap Volume 9.5 L

Benchtop Freeze Dryer

Benchtop Freeze Dryer ADBFD-511
Temperature Range:≤-50℃
Vacuum Level:<10 Pa
Freeze-Dry Area:0.12 m²
Benchtop Freeze Dryer ADBFD-514
Temperature Range:≤-50℃
Vacuum Level <10 Pa:<10 Pa
Freeze-Dry Area :0.07 m²
Benchtop Freeze Dryer ADBFD-512
Temperature Range:≤-50℃
Vacuum Level:<10 Pa
Freeze-Dry Area:0.07 m²
Benchtop Freeze Dryer ADBFD-505
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²
Benchtop Freeze Dryer ADBFD-508
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C
Benchtop Freeze Dryer ADBFD-504
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.11m²
Benchtop Freeze Dryer ADBFD-517
Type:Stoppering chamber
Freeze Dry Area:0.09 m²
Water Capture Capacity:4kg/24h
Benchtop Freeze Dryer ADBFD-513
Temperature Range:≤-50℃
Vacuum Level:<10 Pa
Freeze-Dry Area:0.12 m²
Benchtop Freeze Dryer ADBFD-516
Type:Standard chamber with 8 port manifolds
Freeze Dry Area:0.12m²
Water Capture Capacity:4kg/24h
Benchtop Freeze Dryer ADBFD-501
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²
Benchtop Freeze Dryer ADBFD-510
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C
Benchtop Freeze Dryer ADBFD-509
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C
Benchtop Freeze Dryer ADBFD-503
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²
Benchtop Freeze Dryer ADBFD-515
Type:Standard chamber
Freeze Dry Area:0.12m²
Water Capture Capacity:4kg/24h
Benchtop Freeze Dryer ADBFD-506
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²
Benchtop Freeze Dryer ADBFD-502
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.11m²
Benchtop Freeze Dryer ADBFD-507
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C