| Cold Trap Temperature | -60℃ (below) |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 9.5 L |
| Freeze Drying Area | 0.09 m² |
| Water Capture Capacity | 4 Kg/batch |
| Vacuum Degree | 10 Pa (below) |
| Vacuum Pump | 2 L/s |
| Refrigerant | R600a + R290 + R23 |
| Shelf Quantity | 3 pcs |
| Shelf Space | 70 mm |
| Loading Capacity | 300 ml |
| Total Loading Capacity | 900 ml |
| Tray Size | ф200 × 20 mm |
| Tray Quantity | 3 pcs |
| Vial Capacity |
Ø22:195 vials Ø16:360 vials Ø12:690 |
| Cold Trap Size | ф217 × 250 mm |
| Drying Chamber Dimension | ф240 (260) × 450 mm |
| Noise Level | 66 dB (below) |
| Power Consumption | 0.95 (to1.5) kW |
| Main Unit packing size (W x D x H) | 730 × 600 × 1180 mm |
| Dimension (W x D x H) | 410 × 410 × 640 mm |
| Vacuum Pump packaging size (W x D x H) | 220 × 580 × 370 mm |
| Overall Dimensions (W x D x H) | 480 × 610 × 905 (to 1415) mm |
| Net Weight | 70 (to 83) Kg |
| Gross Weight | 135 (to155) Kg |
The Floor Type Freeze Dryer ADFFD-502 with its large opening and no refrigeration coils inside, is used for sample pre-freezing in pharmaceutical and biotechnology labs to ensure moisture removal before freeze-drying.
Vacuum Pump | 1unit |
Trays | 3 unit |
Drying Rack | 1unit |
Acrylic Cover | 1unit |
Acrylic Bucket | 1unit |
Vacuum Pump Outlet Oil Mist Filter | 1unit |
Vacuum Pump Inlet Dust Filter | 1unit |
Vacuum Pump Inlet Vapor Filter | 1unit |
| Electric Defrosting | 1unit |
| Shelf Heating | 1unit |
1. How is the Floor Type Freeze Dryer different from other types of Freeze Dryers?
The Floor Type Freeze Dryer stands out due to its larger chamber capacity and advanced temperature and vacuum control, making it ideal for large-scale production. Unlike smaller models, it is designed to handle higher sample volumes, making it suitable for commercial and industrial applications. The enhanced digital control system also allows for precise adjustments to ensure optimal drying conditions across various material types.
2. What safety features are included in a Floor Type Freeze Dryer?
Floor Type Freeze Dryers are equipped with multiple safety features, including over-temperature protection, pressure sensors, and emergency shutdown capabilities. These features ensure the system operates within safe parameters, preventing damage to both the equipment and the sample. Additionally, built-in alarms and notifications alert operators to any issues during the drying cycle.
3. What materials are suitable for processing in a Floor Type Freeze Dryer?
Floor Type Freeze Dryers are highly versatile and capable of processing a broad spectrum of materials. Pharmaceuticals, biological samples, food products, and chemical compounds are some of the key materials that benefit from the freeze-drying process. The advanced control systems of these units ensure that each type of material is dried under ideal conditions, preserving both its physical and chemical properties.
4. How does a Floor Type Freeze Dryer enhance product shelf-life?
By removing moisture efficiently and under controlled conditions, a Floor Type Freeze Dryer enhances the shelf life of products. The vacuum and low temperatures prevent microbial growth, oxidation, and chemical degradation, preserving the quality and bioactivity of sensitive materials. This makes Freeze-Drying an excellent choice for products that require long-term storage.
5. What maintenance is required for a Floor Type Freeze Dryer?
Routine maintenance for a Floor Type Freeze Dryer includes checking and cleaning the cold trap, inspecting vacuum seals and sensors, and calibrating temperature and vacuum systems. Regular maintenance ensures optimal performance, extends the lifespan of the equipment, and helps maintain consistent product quality. Operators should follow the manufacturer’s maintenance schedule to avoid unexpected breakdowns.
6. What are the key features of a Floor Type Freeze Dryer?
Floor Type Freeze Dryers are equipped with several key features for efficient, high-quality drying. These include large chamber capacities, which allow for processing larger sample volumes, and programmable controls. Real-time monitoring tracks key parameters like temperature and vacuum pressure, ensuring optimal drying conditions. Low-noise operation makes them suitable for continuous use in laboratory settings.
7. How does a Floor Type Freeze Dryer work?
The Floor Type Freeze Dryer works through a three-stage process. First, the sample is frozen to ultra-low temperatures, turning the water content into ice. Next, during the primary drying phase, a vacuum is applied to sublimate the ice directly into vapor, bypassing the liquid phase. In the secondary drying phase, residual moisture is removed by gradually increasing the temperature. This ensures that the sample reaches its final dry state while preserving its integrity.
8. What is a Floor Type Freeze Dryer used for?
A Floor Type Freeze Dryer is used for efficiently Freeze-Drying large volumes of sensitive materials in industries like pharmaceuticals, biotechnology, food processing, and chemicals. They preserve vaccines, enzymes, plant extracts, and other moisture-sensitive materials by removing moisture through sublimation. This process maintains the integrity, potency, and stability of the sample without altering its structure or bioactivity, making it ideal for long-term storage.
| Temperature Range | ≤–80℃ |
| Vacuum Level | < 10 Pa |
| Total Drying Area | 0.12m² |
| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 28 L |
| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 9.5 L |
| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 28 L |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.11m² |
| Type: | Stoppering chamber |
| Freeze Dry Area: | 0.09 m² |
| Water Capture Capacity: | 4kg/24h |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.11m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.12 m² |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.07 m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Type: | Standard chamber |
| Freeze Dry Area: | 0.12m² |
| Water Capture Capacity: | 4kg/24h |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.12 m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Temperature Range: | ≤-50℃ |
| Vacuum Level <10 Pa: | <10 Pa |
| Freeze-Dry Area : | 0.07 m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Type: | Standard chamber with 8 port manifolds |
| Freeze Dry Area: | 0.12m² |
| Water Capture Capacity: | 4kg/24h |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |