The Floor Type Freeze Dryer ADFFD-505 is an air-cooling unit with a cold trap temperature of below-60°C for moisture capture. It supports nitrogen gas through an inflation valve for oxygen-free drying. A built-in low vacuum alarm enhances safety by monitoring pressure levels during operation. The system maintains vacuum below the set point to reduce drying time. Our Floor Type Freeze Dryer is ideal for pharmaceutical, biotech, and research applications involving sensitive samples.


Cold Trap Temperature ≤ -60℃
Freeze Drying Time 36 to 48 h
Cold Trap Volume 9.5 L
Freeze Drying Area 0.12 (to 0.18) m²
Water Capture Capacity 4 Kg/batch
Vacuum Degree <10 Pa
Vacuum Pump 2 L/s
Refrigerant R600a+R290+R23
Shelf Quantity 4(to 6) pcs
Shelf Space 76(to 50) mm
Loading Capacity 300 ml
Total Loading Capacity 1200 (to 1800) ml
Tray Size ф200 × 20 mm
Tray Quantity 4(to 6) pcs
Vial Capacity Ø22:260 vials
Ø16:480 vials
Ø12:920
Cold Trap Size ф217 × 250 mm
Drying Chamber Dimension Ф240 (260) × 450 mm
Noise Level <66 dB
Power Consumption 0.95 (to1.5) kW
Main Unit packing size (W x D x H) 730 × 600 × 1180 mm
Dimension (W x D x H) 410 × 410 × 640 mm
Vacuum Pump packaging size (W x D x H) 220 × 580 × 370 mm
Overall Dimension (W x D x H) 480 × 610 × 905 (to 1355) mm
Net Weight 70 (to 83) Kg
Gross Weight 135 (to155) Kg
  • Automated control
  • High capacity
  • Ultra-low trap
  • Real-time display
  • Data export

The Floor Type Freeze Dryer ADFFD-505 cold trap with a large opening is ideal for sample pre-freezing, preventing contamination and it is used in pharmaceuticals, biotechnology, and research labs.

Vacuum Pump

1unit

Trays

4 unit

Drying Rack

1unit

Acrylic Cover

1unit

Acrylic Bucket

1unit

Vacuum Pump Outlet Oil Mist Filter

1unit

Vacuum Pump Inlet Dust Filter

1unit

Vacuum Pump Inlet Vapor Filter

1unit

Electric Defrosting

1unit

Shelf Heating

1unit

Floor Type Freeze Dryer ADFFD-505 | Cold Trap Temperature ≤ -60℃ | Freeze Drying Time 36 to 48 h
Floor Type Freeze Dryer ADFFD-505 | Automated control | High capacity

Frequently Asked Questions of Floor Type Freeze Dryer ADFFD-505

1. What makes the Floor Type Freeze Dryer ideal for laboratory and industrial use?

The Floor Type Freeze Dryer offers control over the entire freeze-drying cycle through its advanced PLC system. It allows users to set customized parameters for temperature, pressure, and timing, and reproducible results. Built-in features like vacuum pump start protection, and nitrogen-compatible inflation valves. Its high data storage capacity tracking historical performance. Designed for pharmaceutical, biotechnology, and research labs.

2. What types of applications is the Floor Type Freeze Dryer best suited for?

This Freeze Dryer is designed for use in pharmaceutical manufacturing, biotechnology research, and academic laboratories. It is ideal for drying heat- and oxygen-sensitive samples such as vaccines, enzymes, and plant extracts. With its programmable features and reliable vacuum performance, it ensures gentle drying while preserving the structural and functional integrity of delicate materials.

3. How does the Floor Type Freeze Dryer improve drying efficiency?

The Floor Type Freeze Dryer is designed to maintain vacuum levels below the setpoint, which accelerates the sublimation process. By automating each stage of the freeze-drying cycle, it eliminates delays caused by manual intervention. The cold trap reaches temperatures as low as ? -60°C, ensuring vapor condensation. This combination results in faster cycle completion and higher sample throughput, making it ideal for labs with high processing demands.

4. Is the Floor Type Freeze Dryer suitable for temperature-sensitive samples?

Yes, it is ideal for handling thermally unstable or biologically active compounds. With features like programmable temperature settings, vacuum control, and nitrogen flushing capability, it protects sample integrity throughout the drying process. The controlled environment helps maintain the structure, potency, and viability of delicate materials like enzymes, vaccines, and probiotics. It’s a reliable choice for production labs handling sensitive samples.

5. What kind of maintenance does the Floor Type Freeze Dryer require?

The Floor Type Freeze Dryer includes a vacuum pump maintenance timer to remind users of scheduled service, helping extend pump life and prevent performance issues. The self-diagnosis function monitors the status of key components and alerts users to potential faults. Easy access drain and inflation valves simplify cleaning and maintenance procedures. Regular care ensures longevity and minimizes downtime, making it cost-effective for routine use.

6. What are the key features of a Floor Type Freeze Dryer?

Floor Type Freeze Dryers are equipped with several key features for efficient, high-quality drying. These include large chamber capacities, which allow for processing larger sample volumes, and programmable controls. Real-time monitoring tracks key parameters like temperature and vacuum pressure, ensuring optimal drying conditions. Low-noise operation makes them suitable for continuous use in laboratory settings.

7. How does a Floor Type Freeze Dryer work?

The Floor Type Freeze Dryer works through a three-stage process. First, the sample is frozen to ultra-low temperatures, turning the water content into ice. Next, during the primary drying phase, a vacuum is applied to sublimate the ice directly into vapor, bypassing the liquid phase. In the secondary drying phase, residual moisture is removed by gradually increasing the temperature. This ensures that the sample reaches its final dry state while preserving its integrity.

8. What is a Floor Type Freeze Dryer used for?

A Floor Type Freeze Dryer is used for efficiently Freeze-Drying large volumes of sensitive materials in industries like pharmaceuticals, biotechnology, food processing, and chemicals. They preserve vaccines, enzymes, plant extracts, and other moisture-sensitive materials by removing moisture through sublimation. This process maintains the integrity, potency, and stability of the sample without altering its structure or bioactivity, making it ideal for long-term storage.

Similar Products of Floor Type Freeze Dryer

Temperature Range ≤–80℃
Vacuum Level < 10 Pa
Total Drying Area 0.12m²
Cold Trap Temperature -60℃ (below)
Freeze Drying Time 36 to 48 h
Cold Trap Volume 9.5 L
Cold Trap Temperature ≤ -60℃
Freeze Drying Time 36 to 48 h
Cold Trap Volume 28 L
Cold Trap Temperature ≤ -60℃
Freeze Drying Time 36 to 48 h
Cold Trap Volume 9.5 L

Benchtop Freeze Dryer

Benchtop Freeze Dryer ADBFD-501
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²
Benchtop Freeze Dryer ADBFD-511
Temperature Range:≤-50℃
Vacuum Level:<10 Pa
Freeze-Dry Area:0.12 m²
Benchtop Freeze Dryer ADBFD-516
Type:Standard chamber with 8 port manifolds
Freeze Dry Area:0.12m²
Water Capture Capacity:4kg/24h
Benchtop Freeze Dryer ADBFD-510
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C
Benchtop Freeze Dryer ADBFD-514
Temperature Range:≤-50℃
Vacuum Level <10 Pa:<10 Pa
Freeze-Dry Area :0.07 m²
Benchtop Freeze Dryer ADBFD-513
Temperature Range:≤-50℃
Vacuum Level:<10 Pa
Freeze-Dry Area:0.12 m²
Benchtop Freeze Dryer ADBFD-507
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C
Benchtop Freeze Dryer ADBFD-509
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C
Benchtop Freeze Dryer ADBFD-508
Condenser Temperature:-88 °C
Shelf Temperature Range:-60 °C to +70 °C
Temperature Uniformity:±1 °C
Benchtop Freeze Dryer ADBFD-502
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.11m²
Benchtop Freeze Dryer ADBFD-504
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.11m²
Benchtop Freeze Dryer ADBFD-506
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²
Benchtop Freeze Dryer ADBFD-517
Type:Stoppering chamber
Freeze Dry Area:0.09 m²
Water Capture Capacity:4kg/24h
Benchtop Freeze Dryer ADBFD-503
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²
Benchtop Freeze Dryer ADBFD-515
Type:Standard chamber
Freeze Dry Area:0.12m²
Water Capture Capacity:4kg/24h
Benchtop Freeze Dryer ADBFD-512
Temperature Range:≤-50℃
Vacuum Level:<10 Pa
Freeze-Dry Area:0.07 m²
Benchtop Freeze Dryer ADBFD-505
Temperature Range:≤–80℃
Vacuum Level:< 10 Pa
Total Drying Area:0.27m²