| Maximum Speed | 16500 rpm |
| Maximum RCF | 21630 x g |
| Maximum Capacity | 12 x 10 mL |
| Temperature Range | -20°C to +40°C |
| Temperature Accuracy | ±1°C |
| Available Rotors | No.1, No.2, No.3, No.4 |
| Speed Accuracy | ±10 rpm |
| Time Setting | 1 min to 99 hr 59 min / Pulse |
| Noise | ≤60 dB(A) |
| Power Consumption | 1000 W |
| Dimension | 420 x 625 x 370 mm |
| Net Weight | 53 kg |
| Gross Weight | 65 kg |
Our High Speed Refrigerated Centrifuge ADHSC-517 is widely used in microbiology, pharmaceuticals and forensic science for efficient, temperature-controlled separation of biological sample.
Rotor Type | Capacity | Max Speed | Max RCF | Tube size |
Fixed angle rotor 01 | 12×1.5/2.2ml | 16500 | 19000 | Φ11×42mm |
Fixed angle rotor 02 | 12×5ml | 15000 | 18270 | Φ14×54mm |
Fixed angle rotor 03 | 24×1.5/2.2ml | 15000 | 21630 | Φ11×42mm |
Fixed angle rotor 04 | 12×10ml | 12000 | 13310 | Φ16x86mm |
Fixed angle rotor 05 | 48×1.5/2.2ml | 12000 | 15970 | Φ11×42mm |
1. How easy is it to operate and maintain the High Speed Refrigerated Centrifuge ADHSC-517?
The centrifuge features an intuitive control panel with a digital display for easy operation and monitoring. Users can quickly set parameters like speed, time, and temperature. Maintenance is straightforward due to its user-friendly design and durable components. Routine checks and cleaning help ensure long-lasting performance. The machine also includes alerts for maintenance and error messages, aiding in smooth operation.
2. Is the High Speed Refrigerated Centrifuge ADHSC-517 suitable for different types of laboratory applications?
Yes, the High Speed Refrigerated Centrifuge ADHSC-517 is designed for a wide range of applications including molecular biology, biochemistry, clinical diagnostics, and pharmaceutical research. Its compatibility with various rotors and adapters makes it highly versatile. It can handle tubes, bottles, and microplates depending on the rotor used. The precise control over speed and temperature enhances its adaptability. This makes it an essential tool for any lab requiring high-speed, temperature-controlled centrifugation.
3. What safety features are included in the High Speed Refrigerated Centrifuge ADHSC-517?
The High Speed Refrigerated Centrifuge ADHSC-517 is equipped with essential safety features such as lid interlock, imbalance detection, and over-speed protection. These systems prevent accidents and protect users during operation. The lid remains locked while the rotor is spinning to avoid accidental exposure. Imbalance detection halts the operation if uneven loading occurs. Such safeguards ensure reliable and secure centrifugation in any laboratory environment.
4. How does the refrigeration system in High Speed Refrigerated Centrifuge ADHSC-517 benefit sample processing?
The advanced refrigeration system in the High Speed Refrigerated Centrifuge ADHSC-517 maintains stable low temperatures during high-speed operation. This is crucial for preserving the integrity of heat-sensitive biological and chemical samples. It prevents sample degradation caused by frictional heat. The temperature range is adjustable, offering flexibility for various protocols. Efficient cooling ensures consistent and reliable results throughout the centrifugation process.
5. What is the maximum speed and capacity of the High Speed Refrigerated Centrifuge ADHSC-517?
The High Speed Refrigerated Centrifuge ADHSC-517 offers a high maximum speed, allowing for efficient separation of samples in less time. It supports a variety of rotors to accommodate different tube sizes and capacities. With its robust design, it is ideal for processing both small and large sample volumes. This versatility makes it suitable for research labs, clinical diagnostics, and industrial use. The speed and rotor options ensure optimal performance for high-throughput tasks.
6. What power supply is required for the High Speed Refrigerated Centrifuge ADHSC-517?
The High Speed Refrigerated Centrifuge ADHSC-517 operates on a standard 220V/50Hz power supply, making it suitable for most laboratory electrical systems.
7. Can the High Speed Refrigerated Centrifuge ADHSC-517 be used for clinical diagnostic applications?
Yes, the High Speed Refrigerated Centrifuge ADHSC-517 is designed for clinical diagnostics, including blood sample separation, plasma preparation, and viral load testing.
8. How long can the High Speed Refrigerated Centrifuge ADHSC-517 run continuously?
The High Speed Refrigerated Centrifuge ADHSC-517 supports continuous runs up to 99 minutes or with a hold option for extended durations, depending on the application.
9. How is temperature maintained during high-speed operation in the High Speed Refrigerated Centrifuge ADHSC-517?
The High Speed Refrigerated Centrifuge ADHSC-517 uses advanced refrigeration with automatic temperature compensation to maintain a consistent internal environment even at high speeds.
10. What is a High Speed Refrigerated Centrifuge?
A High Speed Refrigerated Centrifuge is a laboratory instrument that combines high rotational speeds with temperature control to efficiently separate biological samples while preserving their integrity. It is essential for processing heat-sensitive samples by preventing thermal degradation during centrifugation. These centrifuges are widely used in molecular biology, clinical diagnostics, and biochemistry labs.
11. Why is refrigeration important in centrifugation?
Refrigeration helps maintain low temperatures during centrifugation, preventing heat buildup that can degrade temperature-sensitive samples like proteins, enzymes, and nucleic acids. It also minimizes enzymatic activity and preserves the biological function and structure of delicate molecules. This ensures accurate and reliable experimental results.
12. Can the High Speed Refrigerated Centrifuge maintain temperature during the entire run?
Yes, the High Speed Refrigerated Centrifuge system continuously cools the rotor chamber to maintain the set temperature throughout the centrifugation process. This ensures that sensitive samples remain stable and protected from heat-induced damage. Consistent temperature control is critical for reproducible and accurate experimental results.
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 31,405 × g |
| Maximum Capacity | 4 × 750 ml |
| Maximum Speed | 21000 rpm |
| Maximum RCF | 47580 × g |
| Maximum Capacity | 4 × 750 ml |
| Maximum Speed Range | 14,000 rpm |
| Maximum RCF | 18,800 × g |
| Maximum Capacity | 12 × 5 ml |
| Speed | 500 to 15000 rpm, increasement 100 rpm |
| RCF | 100 to 21400×g |
| Temperature Range | -20℃ to +40℃, under room temperature 25℃ |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4499 x g |
| Maximum Capacity: | 4 x 600ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |