| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 9.5 L |
| Freeze Drying Area | 0.12 (to 0.18) m² |
| Water Capture Capacity | 4 Kg/batch |
| Vacuum Degree | <10 Pa |
| Vacuum Pump | 2 L/s |
| Refrigerant | R600a+R290+R23 |
| Shelf Quantity | 4(to 6) pcs |
| Shelf Space | 76(to 50) mm |
| Loading Capacity | 300 ml |
| Total Loading Capacity | 1200 (to 1800) ml |
| Tray Size | ф200 × 20 mm |
| Tray Quantity | 4(to 6) pcs |
| Manifold | 8 pcs |
| Vial Capacity |
Ø22:260 vials Ø16:480 vials Ø12:920 |
| Cold Trap Size | ф217 × 250 mm |
| Drying Chamber Dimension | Ф240 (260) × 450 mm |
| Noise Level | <66 dB |
| Power Consumption | 0.95 (to1.5) kW |
| Main Unit packing size (W x D x H) | 730 × 600 × 1180 mm |
| Dimension (W x D x H) | 410 × 410 × 640 mm |
| Vacuum Pump packaging size (W x D x H) | 220 × 580 × 370 mm |
| Overall Dimension (W x D x H) | 480 × 610 × 905 (to 1355) mm |
| Net Weight | 70 (to 83) Kg |
| Gross Weight | 135 (to155) Kg |
The Floor Type Freeze Dryer ADFFD-507, with a large opening and coil-free cold trap, enables effective pre-freezing of samples in biotech and pharmaceutical labs.
Vacuum Pump | 1unit |
Trays | 4 unit |
Drying Rack | 1unit |
Acrylic Cover | 1unit |
Acrylic Bucket | 1unit |
Drying Flask | 8 unit |
Switch Valve | 8 unit |
Vacuum Pump Outlet Oil Mist Filter | 1unit |
Vacuum Pump Inlet Dust Filter | 1unit |
Vacuum Pump Inlet Vapor Filter | 1unit |
| Electric Defrosting | 1unit |
| Shelf Heating | 1unit |
| 100ml round bottom freeze drying flask | 1unit |
| 200ml round bottom freeze drying flask | 1unit |
| 250ml round bottom freeze drying flask | 1unit |
| 600ml round bottom freeze drying flask | 1unit |
| 1000ml round bottom freeze drying flask | 1unit |
| 1200ml round bottom freeze drying flask | 1unit |
1. How does the Floor Type Freeze Dryer improve drying efficiency?
The Floor Type Freeze Dryer features a controlled vacuum system that reduces drying time. With its cold trap temperature reaching below -60°C, it enhances vapor condensation and accelerates sublimation. The advanced PLC control system automates the drying cycle, minimizing manual intervention. This results in faster cycle completion and higher throughput.
2. What kind of samples can be processed with the Floor Type Freeze Dryer?
This Freeze Dryer is designed to handle heat-sensitive, biologically active samples such as vaccines, enzymes, and probiotics. Its ability to control temperature, pressure, and vacuum levels allows for gentle drying, preserving the structure of delicate materials. The nitrogen-compatible inflation valve ensures oxygen-free drying, crucial for sensitive samples. It is an excellent choice for pharmaceutical and biotechnology labs.
3. Is the Floor Type Freeze Dryer easy to operate and maintain?
Yes, the Floor Type Freeze Dryer is designed for ease of use with its intuitive 7-inch touchscreen interface. The PLC control system offers precise control over the freeze-drying cycle, ensuring reproducibility. Maintenance is simplified with features like vacuum pump maintenance timers and a self-diagnosing system. Regular maintenance ensures longevity and reduces downtime. The dryer’s design allows access for cleaning and servicing.
4. How does the Floor Type Freeze Dryer ensure safety during operation?
The Floor Type Freeze Dryer is equipped with various safety features, including an over vacuum alarm that alerts users to abnormal conditions. The vacuum pump is activated once the cold trap temperature reaches the target. The system’s self-diagnosis feature checks the status of key components, ensuring optimal operation. It includes an acoustic alarm that provides an immediate alert to users in case of malfunctions.
5. How does the Floor Type Freeze Dryer support GMP-compliant environments?
The Floor Type Freeze Dryer is equipped with multi-level password protection to restrict access and ensure that only authorized personnel can adjust settings. The system automatically logs alarms and tracks historical data, providing full traceability for quality control and regulatory audits. These features help ensure compliance with Good Manufacturing Practices standards.
6. What are the key features of a Floor Type Freeze Dryer?
Floor Type Freeze Dryers are equipped with several key features for efficient, high-quality drying. These include large chamber capacities, which allow for processing larger sample volumes, and programmable controls. Real-time monitoring tracks key parameters like temperature and vacuum pressure, ensuring optimal drying conditions. Low-noise operation makes them suitable for continuous use in laboratory settings.
7. How does a Floor Type Freeze Dryer work?
The Floor Type Freeze Dryer works through a three-stage process. First, the sample is frozen to ultra-low temperatures, turning the water content into ice. Next, during the primary drying phase, a vacuum is applied to sublimate the ice directly into vapor, bypassing the liquid phase. In the secondary drying phase, residual moisture is removed by gradually increasing the temperature. This ensures that the sample reaches its final dry state while preserving its integrity.
8. What is a Floor Type Freeze Dryer used for?
A Floor Type Freeze Dryer is used for efficiently Freeze-Drying large volumes of sensitive materials in industries like pharmaceuticals, biotechnology, food processing, and chemicals. They preserve vaccines, enzymes, plant extracts, and other moisture-sensitive materials by removing moisture through sublimation. This process maintains the integrity, potency, and stability of the sample without altering its structure or bioactivity, making it ideal for long-term storage.
| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 28 L |
| Temperature Range | ≤–80℃ |
| Vacuum Level | < 10 Pa |
| Total Drying Area | 0.07m² |
| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 28 L |
| Cold Trap Temperature | ≤ -60℃ |
| Freeze Drying Time | 36 to 48 h |
| Cold Trap Volume | 28 L |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.07 m² |
| Temperature Range: | ≤-50℃ |
| Vacuum Level <10 Pa: | <10 Pa |
| Freeze-Dry Area : | 0.07 m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.11m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.12 m² |
| Type: | Standard chamber with 8 port manifolds |
| Freeze Dry Area: | 0.12m² |
| Water Capture Capacity: | 4kg/24h |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Type: | Stoppering chamber |
| Freeze Dry Area: | 0.09 m² |
| Water Capture Capacity: | 4kg/24h |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.27m² |
| Temperature Range: | ≤–80℃ |
| Vacuum Level: | < 10 Pa |
| Total Drying Area: | 0.11m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |
| Type: | Standard chamber |
| Freeze Dry Area: | 0.12m² |
| Water Capture Capacity: | 4kg/24h |
| Temperature Range: | ≤-50℃ |
| Vacuum Level: | <10 Pa |
| Freeze-Dry Area: | 0.12 m² |
| Condenser Temperature: | -88 °C |
| Shelf Temperature Range: | -60 °C to +70 °C |
| Temperature Uniformity: | ±1 °C |