| Maximum Speed | 18000 rpm |
| Maximum RCF | 29684 × g |
| Maximum Capacity | 6 × 100 ml |
| Temperature Range | -20°C to +40°C |
| Temperature Accuracy | ±1°C |
| Speed Accuracy | ±10 rpm |
| Time Setting | 1 s to 99 h 59 m 59 s |
| Noise | ≤56 dB(A) |
| Power Consumption | 1200 W |
| Dimension | 420 × 520 × 360 mm |
| Weight | 56 kg |
Our High Speed Refrigerated Centrifuge ADHSC-515 is used in genomic research for isolating proteins, in vaccine development for purifying viral particles and in environmental science for separating particulates.
Rotor Type | Capacity | Max Speed | Max RCF | Tube size |
Fixed angle rotor 01 | 12×1.5/2.2ml | 18000rpm | 22675×g | Φ11×42mm |
Fixed angle rotor 02 | 16x 5ml | 15000rpm | 21420×g | Φ14×54mm |
Fixed angle rotor 03 | 24×1.5ml/2.2ml | 17500rpm | 29684×g | Φ11×42mm |
Fixed angle rotor 04 | 12×10ml | 14500rpm | 19439×g | Φ16×86mm |
Fixed angle rotor 05 | 36×1.5/2.2ml | 14500rpm | 20356×g | Φ11×42mm |
Fixed angle rotor 06 | 6×50ml conical bottom | 12000rpm | 15712×g | Φ29×116mm |
Fixed angle rotor 07 | 6×50ml round bottom | 12000rpm | 15712×g | Φ29×111mm |
Fixed angle rotor 08 | 48×1.5/2.2ml | 12000rpm | 15793×g | Φ11×42mm |
Fixed angle rotor 09 | 4×100ml | 11000rpm | 13365×g | Φ38×123mm |
Fixed angle rotor 10 | 8×50ml conical bottom | 11000rpm | 14041×g | Φ29×116mm |
Fixed angle rotor 11 | 8×50ml round bottom | 11000rpm | 13365×g | Φ29×111mm |
Fixed angle rotor 12 | 12×15ml | 11000rpm | 13365×g | Φ17×121mm |
Fixed angle rotor 13 | 6×10ml | 16000rpm | 19004×g | Φ16×86mm |
Fixed angle rotor 14 | 8×15ml | 14000rpm | 17333×g | Φ17×121mm |
Fixed angle rotor 15 | 6×30ml | 14000rpm | 18472×g | Φ25.5×100mm |
Fixed angle rotor 16 | 8x0.2ml PCR strip | 13000rpm | 14643×g | - |
Fixed angle rotor 17 | 6x100ml | 9000rpm | 9771×g | Φ38x123mm |
Fixed angle rotor 18 | 24x2ml (frozen storage tube) | 15000rpm | 23419×g | Φ11.5x45mm |
Microplate rotor 01 | 2x2×48 well plate | 4000rpm | 1538×g | - |
1. What is the maximum speed and capacity of the What is the maximum speed and capacity of the ADHSC-515 centrifuge?
The High-Speed Refrigerated Centrifuge ADHSC-515 offers a maximum speed of up to 18000 rpm, suitable for high-speed separation tasks. It supports a wide range of rotors, accommodating various tube sizes and capacities. The centrifuge is designed for both micro and large-volume sample processing. This versatility makes it ideal for molecular biology, clinical labs, and pharmaceutical applications. Its performance ensures efficient separation of biological, chemical, or clinical samples.
2. Does the High-Speed Refrigerated Centrifuge ADHSC-515 include temperature control features?
Yes, the High-Speed Refrigerated Centrifuge ADHSC-515 is equipped with an advanced refrigeration system that allows precise temperature control typically ranging from -20°C to +40°C. This feature is essential for temperature-sensitive samples like enzymes, blood, and proteins. The system maintains stable cooling even during high-speed runs. It ensures sample integrity and reduces heat buildup during prolonged operation. This makes the unit reliable for long-duration, cold centrifugation.
3. What safety features are integrated into High-Speed Refrigerated Centrifuge ADHSC-515?
The High-Speed Refrigerated Centrifuge ADHSC-515 includes multiple safety features such as lid interlock, imbalance detection, and over-speed protection. These features help prevent accidents and protect both the user and the device. The automatic rotor recognition function enhances operational safety by identifying compatible rotors. Emergency lid release and error display further improve user convenience. Overall, it meets international safety standards for laboratory equipment.
4. Is the High-Speed Refrigerated Centrifuge ADHSC-515 user-friendly and programmable?
Yes, this centrifuge comes with a digital control panel featuring a large LCD display for easy parameter setting and monitoring. It allows users to program speed, time, temperature, and acceleration/deceleration rates. The system can store multiple user-defined programs for repeated use. Its intuitive interface ensures ease of operation for both beginners and experienced lab technicians. The design supports efficient workflow in fast-paced laboratory environments.
5. What are the typical applications of the High-Speed Refrigerated Centrifuge ADHSC-515?
The High-Speed Refrigerated Centrifuge ADHSC-515 is widely used in fields such as molecular biology, biochemistry, pharmaceutical research, clinical diagnostics, and biotechnology. It is suitable for applications involving cell pelleting, protein purification, DNA/RNA extraction, and virus isolation. The precise control and high-speed operation make it ideal for demanding protocols. It’s also used in research institutions and hospitals for routine and specialized tests. Its performance and flexibility make it a valuable asset in any modern lab.
6. What is a High Speed Refrigerated Centrifuge?
A High Speed Refrigerated Centrifuge is a laboratory instrument that combines high rotational speeds with temperature control to efficiently separate biological samples while preserving their integrity. It is essential for processing heat-sensitive samples by preventing thermal degradation during centrifugation. These centrifuges are widely used in molecular biology, clinical diagnostics, and biochemistry labs.
7. Why is refrigeration important in centrifugation?
Refrigeration helps maintain low temperatures during centrifugation, preventing heat buildup that can degrade temperature-sensitive samples like proteins, enzymes, and nucleic acids. It also minimizes enzymatic activity and preserves the biological function and structure of delicate molecules. This ensures accurate and reliable experimental results.
8. Can the High Speed Refrigerated Centrifuge maintain temperature during the entire run?
Yes, the High Speed Refrigerated Centrifuge system continuously cools the rotor chamber to maintain the set temperature throughout the centrifugation process. This ensures that sensitive samples remain stable and protected from heat-induced damage. Consistent temperature control is critical for reproducible and accurate experimental results.
| Max Speed | 22000 rpm |
| Max RCF | 52050 x g |
| Max Capacity | 6x500 ml |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 21,630 × g |
| Maximum Capacity | 12 × 5 ml |
| Max Speed | 10000 rpm |
| Max RCF | 18590 x g |
| Max Capacity | 6x1000 ml |
| Maximum Speed | 22,000 RPM |
| Maximum RCF | 33,873 × g |
| Maximum Capacity | 6 × 100 mL |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4499 x g |
| Maximum Capacity: | 4 x 600ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Maximum Speed: | 7500rpm |
| Maximum RCF: | 3450xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Maximum Speed: | 10000rpm |
| Maximum RCF: | 6100xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Speed Range: | 500 to 12,000 rpm, 500 rpm increments |
| Maximum RCF: | 9,650 × g |
| Capacity: | 32 × 0.2 ml centrifugal tubes <br/> 12 × 0.5/1.5/2.0 ml centrifugal tubes <br/> 4 × 8 × 0.2 ml PCR strips |
| Maximum Speed: | 6000 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | ≤ 2 seconds |
| Speed Range: | 500 to 15000 rpm |
| RCF Range: | 16 to 15080 g |
| Capacity: | 12 x 1.5 / 2.0ml centrifuge tubes |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 2000 g |
| Capacity (Standard): | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Maximum Speed: | 6000rpm |
| Maximum RCF: | 2200xg |
| Capacity: | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Speed Range: | 3000 to 10000 rpm |
| Maximum RCF: | 500 to 5400×g |
| Capacity: | 8×2.0ml/1.5ml/0.5ml centrifuge tube <br/> 4×8×0.2ml PCR tube strips |
| Speed Range: | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF: | 960×g, 4000 rpm <br/> 2200×g, 6000 rpm <br/> 2900×g, 7000 rpm |
| Capacity: | 6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube <br/> 2×8×0.2 ml PCR tube strips |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |