| Maximum Speed | 7500rpm |
| Maximum RCF | 3450xg |
| Capacity | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Time Setting | 1s to 99min59s |
| Noise | ≤52dB(A) |
| Power Supply | AC 100-240V 50/60HZ |
| Dimension | 200x170x130mm |
| Weight | 1.2kg |
Our Mini Centrifuge ADCM-502 is used in clinical labs, research institutions and biotechnology applications for quick and efficient micro-sample separation.
1. What is the Mini Centrifuge ADCM-502 used for?
The Mini Centrifuge ADCM-502 is primarily used for quick spin-downs of microtubes, PCR tubes, and small volume samples. It is commonly utilized in laboratories for sample preparation, enzyme reactions, and micro-filtration. Due to its compact design and ease of use, it’s ideal for personal workstations. It operates efficiently to save time in DNA/RNA protocols or other centrifugation steps. Its versatility makes it suitable for clinical, research, and educational labs.
2. Is the Mini Centrifuge ADCM-502 safe to use?
Yes, the Mini Centrifuge ADCM-502 is equipped with essential safety features such as a lid-lock mechanism that prevents the lid from opening while in use. It also has an automatic shut-off function when the lid is lifted. These features reduce the risk of sample spills and protect the user. Additionally, it is built with a durable outer shell to withstand daily use. The design ensures safe and reliable operation in any lab environment.
3. How to operate the Mini Centrifuge ADCM-502?
The Mini Centrifuge ADCM-502 is designed for ease of use with a simple one-touch operation. Just load the tubes into the rotor, close the lid, and press the button to start spinning. The unit begins automatically once the lid is closed and stops when the lid is opened. This eliminates the need for complex programming or manual speed adjustments. Its intuitive design is perfect for users at all experience levels.
4. What maintenance is required for the Mini Centrifuge ADCM-502?
The Mini Centrifuge ADCM-502 requires minimal maintenance due to its compact and sealed design. Users should regularly clean the rotor chamber with a soft cloth and disinfectant to prevent contamination. It's important to avoid overloading and ensure balanced sample placement. Routine checks for any unusual noise or imbalance are recommended. If any part shows wear or malfunction, it should be serviced by a qualified technician.
5. Is the Mini Centrifuge ADCM-502 noisy during operation?
The Mini Centrifuge ADCM-502 is engineered to operate quietly with minimal vibration. Its brushless motor and well-balanced rotor contribute to smooth and silent functioning. This makes it suitable for use even in noise-sensitive environments like classrooms or shared labs. The low noise also reduces user fatigue during extended use. It complies with standard noise regulations for lab instruments.
6. What is a Mini Centrifuge?
A Mini Centrifuge is typically used for low-speed, quick spin-downs of small liquid samples in laboratories. It is compact, easy to operate, and ideal for personal or benchtop use in research and clinical labs. Mini centrifuges are especially useful for rapid processing of small-volume samples without occupying much workspace.
7. Is it safe to open the Mini Centrifuge while spinning?
No, Mini Centrifuges are designed with safety features to prevent lid opening while spinning. The rotor typically stops automatically when the lid is opened. This prevents accidental exposure to moving parts and minimizes the risk of injury or sample spillage. Always wait for the rotor to come to a complete stop before removing or inserting tubes.
8. What is the proper way to store a Mini Centrifuge when it’s not in use?
To Store the Mini Centrifuge in a clean, dry place with the lid closed. Unplug the unit and remove the rotor if it’s detachable. Avoid storing in areas with high humidity or direct sunlight. Ensure all tubes are removed and the interior is wiped clean to prevent corrosion or contamination. If possible, cover the centrifuge with a dust cover or keep it in a storage cabinet to protect it from environmental debris.
| Maximum Speed | 6000 rpm |
| Maximum RCF | 2000 g |
| Capacity (Standard) | 8 × 1.5 / 2.0 / 0.5 / 0.2 ml |
| Maximum Speed | 10000rpm |
| Maximum RCF | 6100xg |
| Capacity | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml |
| Speed Range | 4000 rpm, 6000 rpm and 7000 rpm, adjustable |
| Maximum RCF |
960×g, 4000 rpm 2200×g, 6000 rpm 2900×g, 7000 rpm |
| Capacity |
6×1.5 ml/2.0 ml, 6×0.5 ml, 16×0.2 ml centrifuge tube 2×8×0.2 ml PCR tube strips |
| Maximum Speed | 6000rpm |
| Maximum RCF | 2200xg |
| Capacity | Three in one rotor:8x1.5/2ml+6x0.5ml+2x8x0.2ml, Rotor for 6 PCR strips |
| Max Speed: | 22000 rpm |
| Max RCF: | 52050 x g |
| Max Capacity: | 6x500 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 21630 x g |
| Maximum Capacity: | 12 x 10 mL |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100ml |
| Maximum Speed: | 15,000 rpm |
| Maximum RCF: | 21,630 × g |
| Maximum Capacity: | 12 × 5 ml |
| Max Speed: | 25000 rpm |
| Max RCF: | 65000 x g |
| Max Capacity: | 4x1000 ml |
| Maximum Speed: | 21,000 rpm |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 4 × 750 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 29684 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 19,000 rpm |
| Maximum RCF: | 30,367× g |
| Maximum Capacity: | 4 x 500 ml |
| Max Speed: | 16000 rpm |
| Max RCF: | 27520 x g |
| Max Capacity: | 6x500 ml |
| Max Speed: | 22000 rpm |
| Max RCF: | 33873x g |
| Max Capacity: | 4x750ml |
| Maximum Speed: | 21000 rpm |
| Maximum RCF: | 47580 × g |
| Maximum Capacity: | 4 × 750 ml |
| Maximum Speed Range: | 14,000 rpm |
| Maximum RCF: | 18,800 × g |
| Maximum Capacity: | 12 × 5 ml |
| Maximum Speed: | 22,000 RPM |
| Maximum RCF: | 33,873 × g |
| Maximum Capacity: | 6 × 100 mL |
| Maximum Speed: | 23,000 rpm |
| Maximum RCF: | 37,023 x g |
| Maximum Capacity: | 4 x 750 ml |
| Max Speed: | 10000 rpm |
| Max RCF: | 18590 x g |
| Max Capacity: | 6x1000 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| RCF: | 100 to 21400×g |
| Temperature Range: | -20℃ to +40℃, under room temperature 25℃ |
| Maximum Speed: | 30000 rpm |
| Maximum RCF: | 65000 × g |
| Maximum Capacity: | 4×1000ml |
| Maximum Speed: | 18,500 rpm |
| Maximum RCF: | 30,025 x g |
| Maximum Capacity: | 4 x 250 ml |
| Max Speed: | 21000 rpm |
| Max RCF: | 47400 x g |
| Max Capacity: | 6x500 ml |
| Max Speed: | 18000 rpm |
| Max RCF: | 31405 x g |
| Max Capacity: | 4 x 250 ml |
| Maximum Speed: | 20,000 RPM |
| Maximum RCF: | 31,405 × g |
| Maximum Capacity: | 6 × 100 ml |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 6 x 100 mL |
| Max Speed: | 4500 rpm |
| Max RCF: | 3380 x g |
| Max Capacity: | 6 x 50 ml syringe |
| Max Speed: | 4700 rpm |
| Max RCF: | 2000 xg |
| Max Capacity: | 12 x 7 ml (SERO rotor) |
| Maximum Speed: | 4500 rpm (adjustable) |
| Maximum RCF: | 2000 × g (adjustable) |
| Maximum Capacity: | 12 × 2 mL tubes (12 mm × 75 mm) |
| Max Speed: | 4000 rpm |
| Max RCF: | 3400 xg |
| Max Capacity: | 4 x 200 ml |
| Max Speed: | 5000 rpm |
| Max RCF: | 5200 × g |
| Max Capacity: | 4 × 800 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123× g |
| Maximum Capacity: | 4x250 ml |
| Max Speed: | 8000 rpm |
| Max RCF: | 14500 × g |
| Max Capacity: | 6x2400 ml / 12 blood bags / 384 blood tubes |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Maximum Speed Range: | 6000 rpm |
| Maximum RCF: | 6880 × g |
| Maximum Capacity: | 6 × 1000 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 5201× g |
| Maximum Capacity: | 4x750 ml |
| Max Capacity: | 4 tubes, each 1000 ml |
| Max Speed: | 6000 rpm |
| Max RCF: | 6693×g |
| Maximum Speed: | 20000 rpm |
| Maximum RCF: | 27994 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 18000 rpm |
| Maximum RCF: | 24814 × g |
| Maximum Capacity: | 6x100 ml |
| Maximum Speed: | 18500 rpm |
| Maximum RCF: | 24760 × g |
| Maximum Capacity: | 4x500 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 21630 × g |
| Maximum Capacity: | 12x5 ml |
| Speed: | 500 to 15000 rpm, increasement 100 rpm |
| Maximum Sample Density: | 1.2g/ml |
| Acceleration/Deceleration : | Ⅰ (≤ 20) <br/> Ⅱ (≤ 40s) <br/> Ⅲ (≤ 60s) |
| Maximum Speed: | 16,500 rpm |
| Maximum RCF: | 24,814 × g |
| Maximum Capacity: | 6 × 100 ml |
| Speed: | 500 to 15000 rpm, 100 rpm increments |
| RCF: | 100 to 15000×g, 100×g increments |
| Maximum Rotor Radius: | 60 mm |
| Maximum Speed: | 16500 rpm |
| Maximum RCF: | 18262× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 15000 rpm |
| Maximum RCF: | 15093× g |
| Maximum Capacity: | 8x5 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 4 × 250 ml |
| Max Speed: | 4200 rpm |
| Max RCF: | 2680 × g |
| Max Capacity: | 4x50ml;12x15ml tube/ blood tube/PRP tube |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 3580 x g |
| Maximum Capacity: | 4x1000 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5123 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 8 × 100 ml |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5201x g |
| Maximum Capacity: | 4x800 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 2680 × g |
| Maximum Capacity: | 24x10ml blood tube |
| Maximum Speed: | 6000 rpm |
| Maximum RCF: | 5200 × g |
| Maximum Capacity: | 4 × 500 ml |
| Maximum Speed: | 4200 rpm |
| Maximum RCF: | 3285 × g |
| Maximum Capacity: | 4 × 100 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4650 × g |
| Maximum Capacity: | 6 × 50 ml |
| Maximum Speed: | 5000 rpm |
| Maximum RCF: | 4499 x g |
| Maximum Capacity: | 4 x 600ml |
| Maximum Speed: | 2800 rpm |
| Maximum RCF: | 600×g |
| Maximum Rotor Radius: | 63 mm |
| Maximum Speed: | 2500 rpm ±5% |
| Rotation Direction : | Anticlockwise (fixed direction) |
| Acceleration Time : | 15 seconds |
| Rotating Speed: | 500 to 2500 rpm |
| RCF Range: | 32 to 797g |
| Capacity: | 2 pcs Microplates or Deep-well plates |
| Rotating Speed: | 2200 to 2800 rpm |
| Maximum RCF: | 550 g |
| Capacity: | 2 PCR plates |
| Maximum Speed: | 3300 rpm |
| Maximum RCF: | 1920 x g |
| Maximum Capacity: | 8 x 30 ml |
| Maximum Speed: | 3840 rpm |
| Maximum RCF: | 1790 xg |
| Maximum Capacity: | 12 Gel card |
| Capacity: | 24 Gel Cards (6 column / 8 column) |
| Speed Range: | 500 to 2200 rpm |
| Timing Range: | 1 min to 30 min |
| Maximum Speed: | 3840 rpm |
| Maximum RCF : | 1790 ×g |
| Capacity : | 24 gel card |
| Maximum Speed: | 3000 rpm |
| Maximum RCF : | 890 × g |
| Maximum Capacity : | 12 cards |
| Maximum Speed: | 4000 rpm |
| Maximum RCF: | 2170 xg |
| Maximum Capacity: | 10 pcs slide glass |
| Max Speed: | 3500 rpm |
| Max RCF: | 1640 xg |
| Max Capacity: | 12x10 ml |
| Max Speed: | 12000 rpm |
| Max RCF: | 15800 xg |
| Capacity: | 24pcs capillary tube |